Direct determination of lead in bones using slurry sampling and high-resolution continuum source electrothermal atomic absorption spectrometry
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F19%3A39914712" target="_blank" >RIV/00216275:25310/19:39914712 - isvavai.cz</a>
Výsledek na webu
<a href="https://pubs.rsc.org/en/content/articlelanding/2019/AY/C8AY02555J#!divAbstract" target="_blank" >https://pubs.rsc.org/en/content/articlelanding/2019/AY/C8AY02555J#!divAbstract</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1039/c8ay02555j" target="_blank" >10.1039/c8ay02555j</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Direct determination of lead in bones using slurry sampling and high-resolution continuum source electrothermal atomic absorption spectrometry
Popis výsledku v původním jazyce
A straightforward, quick, sensitive and reliable method is introduced for the determination of lead in bones using slurry sampling and high-resolution continuum source electrothermal atomic absorption spectrometry (HR-CS-ETAAS). The spectral interference caused by the molecular absorption of PO molecules with rotational fine structure coinciding with the analyte absorption at the most sensitive resonance line 217.001 nm in time was identified and successfully corrected by applying a mathematical correction algorithm using the spectrum obtained by vaporization of hydroxyapatite. The slurry preparation and measuring conditions were determined by means of a response surface methodology. Experiments were designed according to a 2(7-4) replicate (n = 3) fractional factorial design for seven factors (particle size, glycerol and HNO3 concentration, sonication time, concentration of the chemical modifier, pyrolysis and atomization temperature) each at three different levels, including central points. The optimized conditions were 100 mg of a ground sample with particle size < 315 mm, dilution in a liquid-phase composed of 10% w/w glycerol and 5.0% w/w nitric acid solutions, a sonication time of 2 min and the final slurry volume of 10.0 mL. A detection limit of 9.1 ug kg(-1) and characteristic mass of 7.6 pg were achieved using the suggested method under the optimized experimental conditions. Sufficient analyte stabilization was achieved by using 1 ug Pd and 50 ug citric acid. Accurate data were obtained with the use of matrix-free calibration. The accuracy of the method was established by analysing NIST SRM 1486 Bone Meal. Further, the results acquired for ten river otter samples by slurry sampling were compared with those determined after microwave-assisted digestion by inductively coupled plasma time of flight mass spectrometry (TOF-ICP-MS) to assess the accuracy of the method. The results obtained by the two methods were compared using a paired t-test (at the 95% confidence level) and showed no significant difference. The precision of the introduced method was better than 5.5%.
Název v anglickém jazyce
Direct determination of lead in bones using slurry sampling and high-resolution continuum source electrothermal atomic absorption spectrometry
Popis výsledku anglicky
A straightforward, quick, sensitive and reliable method is introduced for the determination of lead in bones using slurry sampling and high-resolution continuum source electrothermal atomic absorption spectrometry (HR-CS-ETAAS). The spectral interference caused by the molecular absorption of PO molecules with rotational fine structure coinciding with the analyte absorption at the most sensitive resonance line 217.001 nm in time was identified and successfully corrected by applying a mathematical correction algorithm using the spectrum obtained by vaporization of hydroxyapatite. The slurry preparation and measuring conditions were determined by means of a response surface methodology. Experiments were designed according to a 2(7-4) replicate (n = 3) fractional factorial design for seven factors (particle size, glycerol and HNO3 concentration, sonication time, concentration of the chemical modifier, pyrolysis and atomization temperature) each at three different levels, including central points. The optimized conditions were 100 mg of a ground sample with particle size < 315 mm, dilution in a liquid-phase composed of 10% w/w glycerol and 5.0% w/w nitric acid solutions, a sonication time of 2 min and the final slurry volume of 10.0 mL. A detection limit of 9.1 ug kg(-1) and characteristic mass of 7.6 pg were achieved using the suggested method under the optimized experimental conditions. Sufficient analyte stabilization was achieved by using 1 ug Pd and 50 ug citric acid. Accurate data were obtained with the use of matrix-free calibration. The accuracy of the method was established by analysing NIST SRM 1486 Bone Meal. Further, the results acquired for ten river otter samples by slurry sampling were compared with those determined after microwave-assisted digestion by inductively coupled plasma time of flight mass spectrometry (TOF-ICP-MS) to assess the accuracy of the method. The results obtained by the two methods were compared using a paired t-test (at the 95% confidence level) and showed no significant difference. The precision of the introduced method was better than 5.5%.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Analytical Methods
ISSN
1759-9660
e-ISSN
—
Svazek periodika
11
Číslo periodika v rámci svazku
9
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
10
Strana od-do
1254-1263
Kód UT WoS článku
000459906000012
EID výsledku v databázi Scopus
—