Flow injection analysis of ranitidine based on derivatization reaction producing 2-methylfuran cation as a sensitive and selective amperometric detector
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F23%3A39919175" target="_blank" >RIV/00216275:25310/23:39919175 - isvavai.cz</a>
Výsledek na webu
<a href="https://analyticalsciencejournals.onlinelibrary.wiley.com/doi/10.1002/elan.202200318" target="_blank" >https://analyticalsciencejournals.onlinelibrary.wiley.com/doi/10.1002/elan.202200318</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/elan.202200318" target="_blank" >10.1002/elan.202200318</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Flow injection analysis of ranitidine based on derivatization reaction producing 2-methylfuran cation as a sensitive and selective amperometric detector
Popis výsledku v původním jazyce
A new electrochemical sensor in a flow injection system is developed for the determination of ranitidine in pharmaceutical formulations. The method is based on the deamination reaction of ranitidine in an acidic environment in the presence of nitrite ions producing the electroactive species 2-methylfuran and releasing nitrosamine [1]. A wide linear range of ranitidine from 4.4 to 6000 mg L−1, with correlation coefficient R2 = 0.996 and the detection limit 1.3 mg L−1 was obtained. The method has been applied in tablet analysis and ampoules; the results are within the confidence limits with 95% reliability compared to the reference method with HPLC.
Název v anglickém jazyce
Flow injection analysis of ranitidine based on derivatization reaction producing 2-methylfuran cation as a sensitive and selective amperometric detector
Popis výsledku anglicky
A new electrochemical sensor in a flow injection system is developed for the determination of ranitidine in pharmaceutical formulations. The method is based on the deamination reaction of ranitidine in an acidic environment in the presence of nitrite ions producing the electroactive species 2-methylfuran and releasing nitrosamine [1]. A wide linear range of ranitidine from 4.4 to 6000 mg L−1, with correlation coefficient R2 = 0.996 and the detection limit 1.3 mg L−1 was obtained. The method has been applied in tablet analysis and ampoules; the results are within the confidence limits with 95% reliability compared to the reference method with HPLC.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10405 - Electrochemistry (dry cells, batteries, fuel cells, corrosion metals, electrolysis)
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electroanalysis
ISSN
1040-0397
e-ISSN
1521-4109
Svazek periodika
35
Číslo periodika v rámci svazku
7
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
10
Strana od-do
"e202200318"
Kód UT WoS článku
000929356100001
EID výsledku v databázi Scopus
2-s2.0-85147556414