Voltammetric Determination of the Total Content of the Most Commonly Occurring Estrogens in Water Media
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F25%3A39923352" target="_blank" >RIV/00216275:25310/25:39923352 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.3390/molecules30030751" target="_blank" >https://doi.org/10.3390/molecules30030751</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/molecules30030751" target="_blank" >10.3390/molecules30030751</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Voltammetric Determination of the Total Content of the Most Commonly Occurring Estrogens in Water Media
Popis výsledku v původním jazyce
Estrogens in aquatic environments pose significant ecological and health risks due to their cumulative effects rather than individual impacts. This study investigates the voltammetric behavior of estrone (E1), 17 beta-estradiol (E2), estriol (E3), and 17 alpha-ethinylestradiol (EE2), presenting a cost-effective and straightforward method for their simultaneous determination. Using differential pulse voltammetry (DPV) with a boron-doped diamond electrode, the method demonstrates high precision (deviations under 4%) and a linear dynamic range of 15.35-134.55 mu mol<middle dot>L-1. Integration of a vacuum evaporation step reduced detection limits to 10-8 mol<middle dot>L-1, enabling effective analysis of real water samples. This optimized approach ensures practical applicability for monitoring total estrogen content in aquatic systems, providing an accessible and reliable alternative to conventional methods.
Název v anglickém jazyce
Voltammetric Determination of the Total Content of the Most Commonly Occurring Estrogens in Water Media
Popis výsledku anglicky
Estrogens in aquatic environments pose significant ecological and health risks due to their cumulative effects rather than individual impacts. This study investigates the voltammetric behavior of estrone (E1), 17 beta-estradiol (E2), estriol (E3), and 17 alpha-ethinylestradiol (EE2), presenting a cost-effective and straightforward method for their simultaneous determination. Using differential pulse voltammetry (DPV) with a boron-doped diamond electrode, the method demonstrates high precision (deviations under 4%) and a linear dynamic range of 15.35-134.55 mu mol<middle dot>L-1. Integration of a vacuum evaporation step reduced detection limits to 10-8 mol<middle dot>L-1, enabling effective analysis of real water samples. This optimized approach ensures practical applicability for monitoring total estrogen content in aquatic systems, providing an accessible and reliable alternative to conventional methods.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Molecules
ISSN
—
e-ISSN
1420-3049
Svazek periodika
30
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
11
Strana od-do
751
Kód UT WoS článku
001418664300001
EID výsledku v databázi Scopus
2-s2.0-85217546452