Checking of Automatically Scaled Ionograms by Infinite Impulse Response Filters
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25530%2F16%3A39901442" target="_blank" >RIV/00216275:25530/16:39901442 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1109/RADIOELEK.2016.7477346" target="_blank" >http://dx.doi.org/10.1109/RADIOELEK.2016.7477346</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/RADIOELEK.2016.7477346" target="_blank" >10.1109/RADIOELEK.2016.7477346</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Checking of Automatically Scaled Ionograms by Infinite Impulse Response Filters
Popis výsledku v původním jazyce
This paper is about using of the infinite impulse response (IIR) filters for the checking of the automatically scaled ionograms. This method is based on the detection of the extreme deviation in the data sequence of the ionospheric parameters (Total Electron Concentration, critical frequency of F2 layer and virtual height of F2 layer). Used types of the IIR filters are low-pass filters (Butterworth, Chebyshev1, Chebyshev2, and Elliptic). Described method using the data from the observatory Pruhonice measured in January 2016 was tested. These data were measured during the geomagnetic storm. Results were very surprising for the virtual height of the layer F2.
Název v anglickém jazyce
Checking of Automatically Scaled Ionograms by Infinite Impulse Response Filters
Popis výsledku anglicky
This paper is about using of the infinite impulse response (IIR) filters for the checking of the automatically scaled ionograms. This method is based on the detection of the extreme deviation in the data sequence of the ionospheric parameters (Total Electron Concentration, critical frequency of F2 layer and virtual height of F2 layer). Used types of the IIR filters are low-pass filters (Butterworth, Chebyshev1, Chebyshev2, and Elliptic). Described method using the data from the observatory Pruhonice measured in January 2016 was tested. These data were measured during the geomagnetic storm. Results were very surprising for the virtual height of the layer F2.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Radioelektronika 2016 : conference proceedings
ISBN
978-1-5090-1674-7
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
273-276
Název nakladatele
IEEE (Institute of Electrical and Electronics Engineers)
Místo vydání
New York
Místo konání akce
Kosice
Datum konání akce
19. 4. 2016
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000383741100057