On rainfall type classification to improve rain attenuation prediction
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25530%2F20%3A39916107" target="_blank" >RIV/00216275:25530/20:39916107 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1109/RADIOELEKTRONIKA49387.2020.9092381" target="_blank" >http://dx.doi.org/10.1109/RADIOELEKTRONIKA49387.2020.9092381</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/RADIOELEKTRONIKA49387.2020.9092381" target="_blank" >10.1109/RADIOELEKTRONIKA49387.2020.9092381</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
On rainfall type classification to improve rain attenuation prediction
Popis výsledku v původním jazyce
In this contribution the one year period of the rain rate measurement in the Czech Republic was analyzed. The measurement was located at the experimental site of the Institute of Atmospheric Physics in the town of Hradec Králové. The measurement was performed by a tipping-bucket rain gauge of high resolution of 0.03 mm of rain amount per one tip and by 2D-videodistrometer from Joaneum Research. This study is focused on rain type classification from which the more precise rain attenuation on microwave link can be predicted. Beside description of simple methods using cheap rain amount and rain rate measurement three methods of sophisticated classification (Tokay-Short, Testud and Waldvogel methods) are described and compared using one year Czech distrometer data.
Název v anglickém jazyce
On rainfall type classification to improve rain attenuation prediction
Popis výsledku anglicky
In this contribution the one year period of the rain rate measurement in the Czech Republic was analyzed. The measurement was located at the experimental site of the Institute of Atmospheric Physics in the town of Hradec Králové. The measurement was performed by a tipping-bucket rain gauge of high resolution of 0.03 mm of rain amount per one tip and by 2D-videodistrometer from Joaneum Research. This study is focused on rain type classification from which the more precise rain attenuation on microwave link can be predicted. Beside description of simple methods using cheap rain amount and rain rate measurement three methods of sophisticated classification (Tokay-Short, Testud and Waldvogel methods) are described and compared using one year Czech distrometer data.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
30th International Conference Radioelektronika, RADIOELEKTRONIKA 2020
ISBN
978-1-72816-469-4
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
1-4
Název nakladatele
IEEE (Institute of Electrical and Electronics Engineers)
Místo vydání
New York
Místo konání akce
Bratislava
Datum konání akce
15. 4. 2020
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—