CONCRETE MIX DESIGN WITH GYPSUM FREE CEMENT
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F02%3APU29327" target="_blank" >RIV/00216305:26110/02:PU29327 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
CONCRETE MIX DESIGN WITH GYPSUM FREE CEMENT
Popis výsledku v původním jazyce
The use of concrete with gypsum free cement (GFCC) requires resolving the issue of mix design. Gypsum free cement concrete are noted for high initial strength. After 3 days the strength of concrete can reach the value comparable with the strength of common cement after 28 days. The concrete with gypsum free cement are identified to repair works and structures which has to be in use very soon, it usually means after 1 or 3 days. Concrete mix design should concern these special properties. For mix designof GFCC is not possible use the same strength equations as for normal gypsum Portland cements, mentioned strength equations consider the 28 days strength. New strength equations for GFCC were elaborated and make possible assessment of strength after from1 to 7 days. Mix design should also consider aggregate porosity, which sould not be more than 25%. Ideal porosity is less than 22%.
Název v anglickém jazyce
CONCRETE MIX DESIGN WITH GYPSUM FREE CEMENT
Popis výsledku anglicky
The use of concrete with gypsum free cement (GFCC) requires resolving the issue of mix design. Gypsum free cement concrete are noted for high initial strength. After 3 days the strength of concrete can reach the value comparable with the strength of common cement after 28 days. The concrete with gypsum free cement are identified to repair works and structures which has to be in use very soon, it usually means after 1 or 3 days. Concrete mix design should concern these special properties. For mix designof GFCC is not possible use the same strength equations as for normal gypsum Portland cements, mentioned strength equations consider the 28 days strength. New strength equations for GFCC were elaborated and make possible assessment of strength after from1 to 7 days. Mix design should also consider aggregate porosity, which sould not be more than 25%. Ideal porosity is less than 22%.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2002
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Zbirnik naukovych prac NDIBK Kyjev
ISSN
0585-4296
e-ISSN
—
Svazek periodika
2002
Číslo periodika v rámci svazku
56
Stát vydavatele periodika
UA - Ukrajina
Počet stran výsledku
8
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—