Long-term tests arrangement for externally strengthened reinforced concrete elements
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F03%3APU39919" target="_blank" >RIV/00216305:26110/03:PU39919 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Long-term tests arrangement for externally strengthened reinforced concrete elements
Popis výsledku v původním jazyce
Methods of external strengthenin of concrete use elements of very high tensional strength glued on tensioned surface of it. These elements may be of metal, carbon fibers (CFRP), glass fibers or others, being ordinarily of very good mechanical properties.But these high strength elements are attached to concrete mostfrequently by epoxy resins. However, epoxy resins are of low Young´s modulus and therefore a higher rate of creep might have influence on long-term behaviour of such external strengthening. IIn order to verify this idea experimentally, special space saving arrangement of tests is described. Panels act like loaded beams and simultaneously like a load for the others of them in a stand. Different load magnitude acting on different layr of panels should make possible to study the long-term influence od degree of shear force on the glue creep. The glue creep may be dependent on type of epoxy resin; therefore more types of it are included in tests.
Název v anglickém jazyce
Long-term tests arrangement for externally strengthened reinforced concrete elements
Popis výsledku anglicky
Methods of external strengthenin of concrete use elements of very high tensional strength glued on tensioned surface of it. These elements may be of metal, carbon fibers (CFRP), glass fibers or others, being ordinarily of very good mechanical properties.But these high strength elements are attached to concrete mostfrequently by epoxy resins. However, epoxy resins are of low Young´s modulus and therefore a higher rate of creep might have influence on long-term behaviour of such external strengthening. IIn order to verify this idea experimentally, special space saving arrangement of tests is described. Panels act like loaded beams and simultaneously like a load for the others of them in a stand. Different load magnitude acting on different layr of panels should make possible to study the long-term influence od degree of shear force on the glue creep. The glue creep may be dependent on type of epoxy resin; therefore more types of it are included in tests.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA103%2F02%2F0749" target="_blank" >GA103/02/0749: Moderní metody zesilování betonových a zděných konstrukcí a optimalizace návrhu</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2003
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceeding of the 3rd international conference on Advanced Engineering Design AED 2003
ISBN
80-86059-35-9
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
91-94
Název nakladatele
Czech Technical University in Prague
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
1. 6. 2003
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—