Stanovení tuhosti podloží rotačně symetrické konstrukce
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F07%3APU71687" target="_blank" >RIV/00216305:26110/07:PU71687 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
čeština
Název v původním jazyce
Stanovení tuhosti podloží rotačně symetrické konstrukce
Popis výsledku v původním jazyce
A subsoil of a structure may be nodeled with various ways in the finite elements method. Winklerś subsoil is often used for models of foundation. Determination of elastic foundation parameters for FEM three-dimensional behavior of cooling tower structure, when substructures have not typical shapes as annular area., may be complicated. A partial axis-sym,etric model of the substructure and its subsoil was created for this problem. The model was loaded with gravity forces of the substructure, structures of columns, structure of cooling tower shell and structure of cooling system. The stiffness characteristics of the soil material for individual elements were changes as a standard imposes with base of various magnitude of vertical stress in the solved model of the subsoil. Program ANSYS was used for solving this problem. This solved settlement of the substructure was a base for compute characteristics of Winklers model.
Název v anglickém jazyce
Stanovení tuhosti podloží rotačně symetrické konstrukce
Popis výsledku anglicky
A subsoil of a structure may be nodeled with various ways in the finite elements method. Winklerś subsoil is often used for models of foundation. Determination of elastic foundation parameters for FEM three-dimensional behavior of cooling tower structure, when substructures have not typical shapes as annular area., may be complicated. A partial axis-sym,etric model of the substructure and its subsoil was created for this problem. The model was loaded with gravity forces of the substructure, structures of columns, structure of cooling tower shell and structure of cooling system. The stiffness characteristics of the soil material for individual elements were changes as a standard imposes with base of various magnitude of vertical stress in the solved model of the subsoil. Program ANSYS was used for solving this problem. This solved settlement of the substructure was a base for compute characteristics of Winklers model.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JM - Inženýrské stavitelství
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
new trends in statics and dynamics of buildings
ISBN
978-80-227-2732-7
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
29-32
Název nakladatele
Neuveden
Místo vydání
Bratislava, Slovensko
Místo konání akce
Bratislava
Datum konání akce
18. 10. 2007
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—