EIS AS A TOOL FOR MEASUREMENTS OF FLOW PROPERTIES ON STEPPED CHUTES
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F09%3APU83259" target="_blank" >RIV/00216305:26110/09:PU83259 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
EIS AS A TOOL FOR MEASUREMENTS OF FLOW PROPERTIES ON STEPPED CHUTES
Popis výsledku v původním jazyce
Several dams in the Check Republic are equipped with stepped chutes. Most of them are around 100-years old. Safety of these dams has been reevaluated according to the new legislature recently. The safety management of 10 000-years flood is demanded now.To comply with this requirement a significant upgrades of their safety structures have to be often proposed and further assessed using hydraulic research. However, this issue is not easy since a strong aeration combined with several flow regimes occur while the water flows along the stepped chute. Therefore, traditional gauges as a point gauge, Pitot tube, or micro-propellers fails. Here the electrical based methods are often involved. This paper summarizes results from the research of flow along an artificial stepped chute where the electrical impedance spectrometry was involved for measurements of the flow properties.
Název v anglickém jazyce
EIS AS A TOOL FOR MEASUREMENTS OF FLOW PROPERTIES ON STEPPED CHUTES
Popis výsledku anglicky
Several dams in the Check Republic are equipped with stepped chutes. Most of them are around 100-years old. Safety of these dams has been reevaluated according to the new legislature recently. The safety management of 10 000-years flood is demanded now.To comply with this requirement a significant upgrades of their safety structures have to be often proposed and further assessed using hydraulic research. However, this issue is not easy since a strong aeration combined with several flow regimes occur while the water flows along the stepped chute. Therefore, traditional gauges as a point gauge, Pitot tube, or micro-propellers fails. Here the electrical based methods are often involved. This paper summarizes results from the research of flow along an artificial stepped chute where the electrical impedance spectrometry was involved for measurements of the flow properties.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
EUREKA 2009
ISBN
978-80-214-3969-6
ISSN
—
e-ISSN
—
Počet stran výsledku
7
Strana od-do
—
Název nakladatele
VUTIUM
Místo vydání
Brno
Místo konání akce
Svratka
Datum konání akce
11. 11. 2009
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—