Assessment of tanks with fluids subjected to seismic excitation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F11%3APU96851" target="_blank" >RIV/00216305:26110/11:PU96851 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Assessment of tanks with fluids subjected to seismic excitation
Popis výsledku v původním jazyce
Checking analyses of large steel tanks with fluid have been carried out within the frame of the project of completion of Units 3 a 4 of the nuclear power plant Mochovce. The calculations have been carried out in accordance with the regulations NTD A.S.I.The calculations include the assessment of the tank resistance to seismic loads. The seismic analysis is based on the specified level of ground acceleration, for which the necessary floor response spectra have been generated. Problems have appeared withcomputation of responses of tanks with fluid. The applied ANSYS program package does not allow (for the time being) a correct response spectrum analysis with the use of FLUID30 finite elements. The application of FLUID80 elements is questionable, yet acceptable with cross-checking solution using FLUID30 elements. The paper contains procedure applied for the calculation of the convective mode frequency and the respective fluid pressure field. The resultant seismic responses of analyzed t
Název v anglickém jazyce
Assessment of tanks with fluids subjected to seismic excitation
Popis výsledku anglicky
Checking analyses of large steel tanks with fluid have been carried out within the frame of the project of completion of Units 3 a 4 of the nuclear power plant Mochovce. The calculations have been carried out in accordance with the regulations NTD A.S.I.The calculations include the assessment of the tank resistance to seismic loads. The seismic analysis is based on the specified level of ground acceleration, for which the necessary floor response spectra have been generated. Problems have appeared withcomputation of responses of tanks with fluid. The applied ANSYS program package does not allow (for the time being) a correct response spectrum analysis with the use of FLUID30 finite elements. The application of FLUID80 elements is questionable, yet acceptable with cross-checking solution using FLUID30 elements. The paper contains procedure applied for the calculation of the convective mode frequency and the respective fluid pressure field. The resultant seismic responses of analyzed t
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JM - Inženýrské stavitelství
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA103%2F09%2F2007" target="_blank" >GA103/09/2007: Vliv technické a přírodní seizmicity na statickou spolehlivost a životnost staveb</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
17th International Conference, ENGINEERING MECHANICS 2011
ISBN
978-80-87012-33-8
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
87-90
Název nakladatele
Neuveden
Místo vydání
Svratka
Místo konání akce
Svratka
Datum konání akce
9. 5. 2011
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—