BSim Simulation of Indoor Climate of Romanesque Rotunda in Znojmo
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F13%3APU104088" target="_blank" >RIV/00216305:26110/13:PU104088 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
BSim Simulation of Indoor Climate of Romanesque Rotunda in Znojmo
Popis výsledku v původním jazyce
Historical buildings require a specific indoor climate to preserve their maximum authenticity, especially when there is a valuable fresco decoration in the historical building. Such a sample in the Czech Republic is the Romanesque St. Catherine rotunda in Znojmo. The most suitable microclimate for such objects with a fresco decoration is defined in UNI 10829:1999, which results from long-time experience of Italian specialists. Parameters recommended by an Italian standard are theoretically tested by theBSim simulation in local climatic conditions. A detailed numerical simulation also takes into account an impact of the floor heating system, which heats the Romanesque rotunda object in the winter period. Results obtained from the BSim simulation are subsequently compared with actually measured data in the rotunda object.
Název v anglickém jazyce
BSim Simulation of Indoor Climate of Romanesque Rotunda in Znojmo
Popis výsledku anglicky
Historical buildings require a specific indoor climate to preserve their maximum authenticity, especially when there is a valuable fresco decoration in the historical building. Such a sample in the Czech Republic is the Romanesque St. Catherine rotunda in Znojmo. The most suitable microclimate for such objects with a fresco decoration is defined in UNI 10829:1999, which results from long-time experience of Italian specialists. Parameters recommended by an Italian standard are theoretically tested by theBSim simulation in local climatic conditions. A detailed numerical simulation also takes into account an impact of the floor heating system, which heats the Romanesque rotunda object in the winter period. Results obtained from the BSim simulation are subsequently compared with actually measured data in the rotunda object.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/EE2.3.30.0039" target="_blank" >EE2.3.30.0039: Excelentní mladí vědci na VUT v Brně</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of CLIMA 2013
ISBN
978-80-260-4001-9
ISSN
—
e-ISSN
—
Počet stran výsledku
10
Strana od-do
614-623
Název nakladatele
Society of Environmental Engineering (STP)
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
16. 6. 2013
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—