Thermal Insulation Materials for Structural Details: Comparison of Environmental Impacts
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F13%3APU105124" target="_blank" >RIV/00216305:26110/13:PU105124 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Thermal Insulation Materials for Structural Details: Comparison of Environmental Impacts
Popis výsledku v původním jazyce
This paper presents a comparison of selected environmental impacts of thermal insulation installation into a structural detail located at the base of the wall. This is a specific detail as the used thermal insulation is exposed to high mechanical loads. Therefore, the use of standard insulation materials, such as expanded polystyrene or mineral wool, is impossible. Two variants of the thermal insulation were used in the assessment. The first one is a common (in such structural detail) installation of expanded glass slabs. The other one is the use of structural elements made of thermal insulation composite material developed at Faculty of Civil Engineering, Brno University of Technology, Czech Republic. The environmental impacts were identified with the use of LCA (Life Cycle Assessment) methodology in GaBi 4 software tool. Environmental impacts of foam glass installation were taken from databases. Environmental impacts of developed composite material were calculated.
Název v anglickém jazyce
Thermal Insulation Materials for Structural Details: Comparison of Environmental Impacts
Popis výsledku anglicky
This paper presents a comparison of selected environmental impacts of thermal insulation installation into a structural detail located at the base of the wall. This is a specific detail as the used thermal insulation is exposed to high mechanical loads. Therefore, the use of standard insulation materials, such as expanded polystyrene or mineral wool, is impossible. Two variants of the thermal insulation were used in the assessment. The first one is a common (in such structural detail) installation of expanded glass slabs. The other one is the use of structural elements made of thermal insulation composite material developed at Faculty of Civil Engineering, Brno University of Technology, Czech Republic. The environmental impacts were identified with the use of LCA (Life Cycle Assessment) methodology in GaBi 4 software tool. Environmental impacts of foam glass installation were taken from databases. Environmental impacts of developed composite material were calculated.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
International Journal of Civil and Environmental Engineering
ISSN
1701-8285
e-ISSN
—
Svazek periodika
35
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
IN - Indická republika
Počet stran výsledku
6
Strana od-do
1163-1168
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—