Load bearing capacity of composite slab is very often governed by their shear bearing capacity. Design of new types of sheeting according to nowadays building codes is burdened by necessity of performing full-scale laboratory bending tests which is expensive and time consuming. Usage of small-scale shear tests presents a less-expensive alternative; however shear tests do not include all the aspects affecting the bearing capacity of bended slab. A recalculation procedure is therefore needed. Slip-block test procedure uses test arrangement which enables to obtain coefficient of friction and effect of mechanical interlock separately. This results in relatively simple method which enables to calculate load bearing capacity of composite slab for different load arrangements. Small-scale tests are not normalized therefore it is necessary to be performed in proper way in order to obtain correct results. Test results from two different laboratories are being compared in this paper.
Název v anglickém jazyce
Small-Scale Test for Composite Steel-Concrete Slab Design
Popis výsledku anglicky
Load bearing capacity of composite slab is very often governed by their shear bearing capacity. Design of new types of sheeting according to nowadays building codes is burdened by necessity of performing full-scale laboratory bending tests which is expensive and time consuming. Usage of small-scale shear tests presents a less-expensive alternative; however shear tests do not include all the aspects affecting the bearing capacity of bended slab. A recalculation procedure is therefore needed. Slip-block test procedure uses test arrangement which enables to obtain coefficient of friction and effect of mechanical interlock separately. This results in relatively simple method which enables to calculate load bearing capacity of composite slab for different load arrangements. Small-scale tests are not normalized therefore it is necessary to be performed in proper way in order to obtain correct results. Test results from two different laboratories are being compared in this paper.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
16. odborná konference doktorského studia JUNIORSTAV 2014
ISBN
978-80-214-4851-3
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
1-6
Název nakladatele
Vysoké učení technické v Brně
Místo vydání
Brno
Místo konání akce
Brno
Datum konání akce
30. 1. 2014
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—