Wooden Facade and Determination of Strength of Bonded Timber Joints
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F14%3APU111674" target="_blank" >RIV/00216305:26110/14:PU111674 - isvavai.cz</a>
Výsledek na webu
<a href="http://arsa-conf.com/archive/?vid=1&aid=2&kid=60301-72" target="_blank" >http://arsa-conf.com/archive/?vid=1&aid=2&kid=60301-72</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Wooden Facade and Determination of Strength of Bonded Timber Joints
Popis výsledku v původním jazyce
A research case focused on vented wooden façade system with bonded joints is presented in this paper. The potential of bonded joints is studied and described in more detail and verified through experimental measurements. For the purpose of tests spruce timber profiles were chosen for the load bearing substructure and Wooden plastic composite façade sheeting for the cladding. Three types of industrial adhesives intended for structural bonding were selected. The article is focused on the preparation as well as on the subsequent experimental verification of substructure bonding retention to the cladding. The adhesive bonds were tested both in tension as well as in shear at a temperature of (293.15+/-3) K and a relative humidity of (55+/-10) %. The test results proved the fact that bonded joints are more than suitable alternative to the mechanical joints. During the tests appeared some differences in stability and failure behaviour between the adhesive systems as well as within the sheeting material. Additionally, the suitability of selected group of adhesives in combination with wooden plastic cladding material as well as with the timber substructure was confirmed.
Název v anglickém jazyce
Wooden Facade and Determination of Strength of Bonded Timber Joints
Popis výsledku anglicky
A research case focused on vented wooden façade system with bonded joints is presented in this paper. The potential of bonded joints is studied and described in more detail and verified through experimental measurements. For the purpose of tests spruce timber profiles were chosen for the load bearing substructure and Wooden plastic composite façade sheeting for the cladding. Three types of industrial adhesives intended for structural bonding were selected. The article is focused on the preparation as well as on the subsequent experimental verification of substructure bonding retention to the cladding. The adhesive bonds were tested both in tension as well as in shear at a temperature of (293.15+/-3) K and a relative humidity of (55+/-10) %. The test results proved the fact that bonded joints are more than suitable alternative to the mechanical joints. During the tests appeared some differences in stability and failure behaviour between the adhesive systems as well as within the sheeting material. Additionally, the suitability of selected group of adhesives in combination with wooden plastic cladding material as well as with the timber substructure was confirmed.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/FR-TI4%2F332" target="_blank" >FR-TI4/332: Nové technologie lepených obvodových plášťů budov s kotvícími prvky se zvýšenou odolností vůči korozi</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings in Advanced Research in Scientific Areas (ARSA 2014)
ISBN
978-80-554-0958-0
ISSN
1338-9831
e-ISSN
—
Počet stran výsledku
5
Strana od-do
331-335
Název nakladatele
EDIS - Publishing Institution of the University of Zilina
Místo vydání
Žilina
Místo konání akce
Žilina
Datum konání akce
1. 12. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—