Different Options for Foundations of Buildings in Thermal and Financial Context
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F14%3APU111854" target="_blank" >RIV/00216305:26110/14:PU111854 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Different Options for Foundations of Buildings in Thermal and Financial Context
Popis výsledku v původním jazyce
Great emphasis is placed nowadays not only on the quality of the building envelope, but also the financial costs associated with this solution. One of the places that have an impact on the quality design of the building envelope is the connection of thebuilding to the foundation structure. There are many variants that can be used in addressing this structural detail. This article describes the most common variants used for building facilities based on the foundation strips. These variants are supplemented with their financial evaluation. The study was conducted on an idealized facility with ground plant dimensions of 10.9 m x 10.2 m. The masonry was considered to be built to a height of 1 m above the base concrete slab. Individual variants are mutually compared in thermal and technical terms using the linear thermal transmittance coefficient determined in accordance with CSN EN ISO 10 211 [1] a CSN EN ISO 13 370 [2], but also from the economic point of view.
Název v anglickém jazyce
Different Options for Foundations of Buildings in Thermal and Financial Context
Popis výsledku anglicky
Great emphasis is placed nowadays not only on the quality of the building envelope, but also the financial costs associated with this solution. One of the places that have an impact on the quality design of the building envelope is the connection of thebuilding to the foundation structure. There are many variants that can be used in addressing this structural detail. This article describes the most common variants used for building facilities based on the foundation strips. These variants are supplemented with their financial evaluation. The study was conducted on an idealized facility with ground plant dimensions of 10.9 m x 10.2 m. The masonry was considered to be built to a height of 1 m above the base concrete slab. Individual variants are mutually compared in thermal and technical terms using the linear thermal transmittance coefficient determined in accordance with CSN EN ISO 10 211 [1] a CSN EN ISO 13 370 [2], but also from the economic point of view.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
enviBUILD 2014
ISBN
978-80-214-5003-5
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
1-5
Název nakladatele
Trans tech publications
Místo vydání
Neuveden
Místo konání akce
Brno
Datum konání akce
18. 9. 2014
Typ akce podle státní příslušnosti
EUR - Evropská akce