Influence of open joints in ventilated façade cladding
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F15%3APU114295" target="_blank" >RIV/00216305:26110/15:PU114295 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Influence of open joints in ventilated façade cladding
Popis výsledku v původním jazyce
Implementation of open joints can influence distribution of temperatures and air flow in the ventilated façade. Air flow and temperature in the cavity relates to energy demands of building and construction requirements. It is important also for the efficiency of photovoltaic façades. Temperature and air velocity were investigated in the ventilated façade cavity using experimental measurement. Used model consists of two sections differ in the type of cladding. The first section was fitted with small cladding parts with open joints between adjacent cladding parts. The second section was fitted with one cladding part on the whole height of ventilated cavity. The influence of open joints was investigated by temperature and air velocity comparison of described sections during one week in summer season. The aim of this work is to study and theoretically describe that the open joints in insolated ventilated façade constructions can cause various differences of cavity temperatures. Results sho
Název v anglickém jazyce
Influence of open joints in ventilated façade cladding
Popis výsledku anglicky
Implementation of open joints can influence distribution of temperatures and air flow in the ventilated façade. Air flow and temperature in the cavity relates to energy demands of building and construction requirements. It is important also for the efficiency of photovoltaic façades. Temperature and air velocity were investigated in the ventilated façade cavity using experimental measurement. Used model consists of two sections differ in the type of cladding. The first section was fitted with small cladding parts with open joints between adjacent cladding parts. The second section was fitted with one cladding part on the whole height of ventilated cavity. The influence of open joints was investigated by temperature and air velocity comparison of described sections during one week in summer season. The aim of this work is to study and theoretically describe that the open joints in insolated ventilated façade constructions can cause various differences of cavity temperatures. Results sho
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Young Scientist 2015
ISBN
978-80-553-1988-9
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
1-5
Název nakladatele
Technical University of Košice
Místo vydání
Technical University of Košice, Faculty of Civil
Místo konání akce
Jasná
Datum konání akce
8. 4. 2015
Typ akce podle státní příslušnosti
WRD - Celosvětová akce