The Suitability of Sealants for Use with Concrete Structures
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F15%3APU114657" target="_blank" >RIV/00216305:26110/15:PU114657 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.4028/www.scientific.net/AMR.1122.131" target="_blank" >http://dx.doi.org/10.4028/www.scientific.net/AMR.1122.131</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.4028/www.scientific.net/AMR.1122.131" target="_blank" >10.4028/www.scientific.net/AMR.1122.131</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The Suitability of Sealants for Use with Concrete Structures
Popis výsledku v původním jazyce
Building reconstruction is rather a broad term encapsulating the implementation of solutions to the unsatisfactory condition of various parts of a built structure, which includes the solution of issues concerning the penetration of undesired humidity inthe liquid state through leaks in the building?s outer shell. This contribution deals with issues involved in the sealing of concrete elements in the outer shell structures of buildings using modern sealants. It involves the experimental testing of sealed joints using test samples fabricated from glass fibre reinforced concrete and fibre-cement facade cladding panels in combination with various commonly accessible sealants. The sealants were exposed to tensile stress under various environmental conditions, as well as cyclic stress. The results of the tests provide a comprehensive picture of sealants? adhesion and cohesion with the test substrates and clearly show the suitability or unsuitability of their application on substrates with c
Název v anglickém jazyce
The Suitability of Sealants for Use with Concrete Structures
Popis výsledku anglicky
Building reconstruction is rather a broad term encapsulating the implementation of solutions to the unsatisfactory condition of various parts of a built structure, which includes the solution of issues concerning the penetration of undesired humidity inthe liquid state through leaks in the building?s outer shell. This contribution deals with issues involved in the sealing of concrete elements in the outer shell structures of buildings using modern sealants. It involves the experimental testing of sealed joints using test samples fabricated from glass fibre reinforced concrete and fibre-cement facade cladding panels in combination with various commonly accessible sealants. The sealants were exposed to tensile stress under various environmental conditions, as well as cyclic stress. The results of the tests provide a comprehensive picture of sealants? adhesion and cohesion with the test substrates and clearly show the suitability or unsuitability of their application on substrates with c
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/FR-TI4%2F332" target="_blank" >FR-TI4/332: Nové technologie lepených obvodových plášťů budov s kotvícími prvky se zvýšenou odolností vůči korozi</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Advanced Materials Research
ISSN
1022-6680
e-ISSN
—
Svazek periodika
2015(1122)
Číslo periodika v rámci svazku
1122
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
4
Strana od-do
131-134
Kód UT WoS článku
—