Numerical Simulation of Subsoil Freezing Risk under the Freezer Room
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F15%3APU117279" target="_blank" >RIV/00216305:26110/15:PU117279 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.4028/www.scientific.net/AMM.797.225" target="_blank" >http://dx.doi.org/10.4028/www.scientific.net/AMM.797.225</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.4028/www.scientific.net/AMM.797.225" target="_blank" >10.4028/www.scientific.net/AMM.797.225</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Numerical Simulation of Subsoil Freezing Risk under the Freezer Room
Popis výsledku v původním jazyce
The article deals with risks of subsoil freezing which lead to volumetric changes of frozen water contained in the soil. These changes can cause damage of foundations of building objects. The issue was solved by steady-state and transient 1D and 2D numerical simulations of heat conduction in the floor and subsoil under a freezer room. These simulations were performed in software CalA. Several possibilities of operating conditions of the freezer room were examined within different boundary conditions. Impact of different simulation setups on subsoil temperature fields was observed. Use of exhaust heat from condenser of a freezing system is suitable method for thermal activation of the floor structure. This solution eliminates risks of subsoil freezing more economically than commonly used electrical heating cables.
Název v anglickém jazyce
Numerical Simulation of Subsoil Freezing Risk under the Freezer Room
Popis výsledku anglicky
The article deals with risks of subsoil freezing which lead to volumetric changes of frozen water contained in the soil. These changes can cause damage of foundations of building objects. The issue was solved by steady-state and transient 1D and 2D numerical simulations of heat conduction in the floor and subsoil under a freezer room. These simulations were performed in software CalA. Several possibilities of operating conditions of the freezer room were examined within different boundary conditions. Impact of different simulation setups on subsoil temperature fields was observed. Use of exhaust heat from condenser of a freezing system is suitable method for thermal activation of the floor structure. This solution eliminates risks of subsoil freezing more economically than commonly used electrical heating cables.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Science and Engineering 2015
ISBN
978-3-03835-542-7
ISSN
1662-7482
e-ISSN
—
Počet stran výsledku
6
Strana od-do
225-230
Název nakladatele
Trans Tech Publications
Místo vydání
Płock
Místo konání akce
Płock
Datum konání akce
5. 11. 2015
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—