Determination of Thermal Conductivity on Lightweight Concretes
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F16%3APU116708" target="_blank" >RIV/00216305:26110/16:PU116708 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.4028/www.scientific.net/KEM.677.163" target="_blank" >http://dx.doi.org/10.4028/www.scientific.net/KEM.677.163</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.4028/www.scientific.net/KEM.677.163" target="_blank" >10.4028/www.scientific.net/KEM.677.163</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of Thermal Conductivity on Lightweight Concretes
Popis výsledku v původním jazyce
A range of testing methods were used to study the potential structural changes as a result of the effects of high temperatures on lightweight types of concrete developed above all for fire resistant structures. One such test for monitoring changes in concrete structures is the non-stationary determination of the coefficient of thermal conductivity using the hot wire method. The matrix structure progressively collapses as a result of the effects of high temperatures on the concrete structure´s surface because erosion takes place of the matrix and aggregate porous structures. The degradation of the porosity of the concrete results in the deterioration of its thermal insulating properties. This paper assesses the dependence of the thermal conductivity coefficient of lightweight concretes on temperature and determines the potential occurrence of structural changes in the lightweight concrete matrix. The results were verified using other methods to determine the concrete´s resistance to thermal load.
Název v anglickém jazyce
Determination of Thermal Conductivity on Lightweight Concretes
Popis výsledku anglicky
A range of testing methods were used to study the potential structural changes as a result of the effects of high temperatures on lightweight types of concrete developed above all for fire resistant structures. One such test for monitoring changes in concrete structures is the non-stationary determination of the coefficient of thermal conductivity using the hot wire method. The matrix structure progressively collapses as a result of the effects of high temperatures on the concrete structure´s surface because erosion takes place of the matrix and aggregate porous structures. The degradation of the porosity of the concrete results in the deterioration of its thermal insulating properties. This paper assesses the dependence of the thermal conductivity coefficient of lightweight concretes on temperature and determines the potential occurrence of structural changes in the lightweight concrete matrix. The results were verified using other methods to determine the concrete´s resistance to thermal load.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Special Concrete and Composites 2015
ISBN
978-3-03835-579-3
ISSN
1013-9826
e-ISSN
—
Počet stran výsledku
6
Strana od-do
163-168
Název nakladatele
Trans Tech Publications
Místo vydání
Švýcarsko
Místo konání akce
Skalský dvůr
Datum konání akce
15. 10. 2015
Typ akce podle státní příslušnosti
EUR - Evropská akce