Compare of Experimental and Numerical Evaluation of Structure with Application of Reflective Insulation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F16%3APU119538" target="_blank" >RIV/00216305:26110/16:PU119538 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.4028/www.scientific.net/AMM.824.34" target="_blank" >http://dx.doi.org/10.4028/www.scientific.net/AMM.824.34</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.4028/www.scientific.net/AMM.824.34" target="_blank" >10.4028/www.scientific.net/AMM.824.34</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Compare of Experimental and Numerical Evaluation of Structure with Application of Reflective Insulation
Popis výsledku v původním jazyce
Thermal insulation effect of reflective insulation is based on the reflection of thermal radiation. Reflective insulations are mainly used in combination with the non-ventilated air cavity. Proposed paper deals with experimental measurements of the thermal insulation properties of the air cavity surrounded by low-emissivity surfaces and comparison of measured values with calculated values according to the standardized procedures. The beginning for determination of the thermal resistance of air cavity was to conduct several experimental measurements by Hot Box method using heat flow meter. The results show good agreement between measured and calculated data.
Název v anglickém jazyce
Compare of Experimental and Numerical Evaluation of Structure with Application of Reflective Insulation
Popis výsledku anglicky
Thermal insulation effect of reflective insulation is based on the reflection of thermal radiation. Reflective insulations are mainly used in combination with the non-ventilated air cavity. Proposed paper deals with experimental measurements of the thermal insulation properties of the air cavity surrounded by low-emissivity surfaces and comparison of measured values with calculated values according to the standardized procedures. The beginning for determination of the thermal resistance of air cavity was to conduct several experimental measurements by Hot Box method using heat flow meter. The results show good agreement between measured and calculated data.
Klasifikace
Druh
J<sub>ost</sub> - Ostatní články v recenzovaných periodicích
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Applied Mechanics and Materials
ISSN
1662-7482
e-ISSN
—
Svazek periodika
2016
Číslo periodika v rámci svazku
824
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
9
Strana od-do
34-42