Popis výsledku v původním jazyce
The article deals with analysis of the heat balance and temperature microclimate of indoor space of a four-storey building atrium. With regard to the anticipated thermal loads in all functionally connected rooms, investor made a request to verify the thermal stability of the atrium before the implementation stage. Atrium and adjacent rooms are a geometrically complicated inner space which cannot be solved by analytical methods to ensure the required temperature conditions in occupied zone. This led to the creation of a mathematical model of the atrium with the current project solution. The result of the simulation of the existing solutions is that there is not complied desired air temperature in the occupied zone. For this reason, it was developed optimization of existing variant. Optimization was performed in steps as changing temperature of the central air conditioning system, changing number of units and performance of local refrigeration air conditioning. The conclusion of this paper is to evaluate the thermal profiles of temperature stratification in the atrium area and request the required cooling performance of the ventilation system. The article attempts to use computer modelling as a tool for the placement and performance design of ventilation equipment.
Název v anglickém jazyce
Optimization of Thermal Stability of Atrium based on Computational Modeling
Popis výsledku anglicky
The article deals with analysis of the heat balance and temperature microclimate of indoor space of a four-storey building atrium. With regard to the anticipated thermal loads in all functionally connected rooms, investor made a request to verify the thermal stability of the atrium before the implementation stage. Atrium and adjacent rooms are a geometrically complicated inner space which cannot be solved by analytical methods to ensure the required temperature conditions in occupied zone. This led to the creation of a mathematical model of the atrium with the current project solution. The result of the simulation of the existing solutions is that there is not complied desired air temperature in the occupied zone. For this reason, it was developed optimization of existing variant. Optimization was performed in steps as changing temperature of the central air conditioning system, changing number of units and performance of local refrigeration air conditioning. The conclusion of this paper is to evaluate the thermal profiles of temperature stratification in the atrium area and request the required cooling performance of the ventilation system. The article attempts to use computer modelling as a tool for the placement and performance design of ventilation equipment.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Applied Mechanics and Materials
ISSN
1662-7482
e-ISSN
—
Svazek periodika
2016
Číslo periodika v rámci svazku
861
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
8
Strana od-do
353-360
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—