Popis výsledku v původním jazyce
Daylight in buildings can be evaluated using dynamic and static daylight metrics. The daylight factor is a static daylight metric which evaluates daylight conditions under the overcast sky model according to the International Commission on Illumination. However, the dynamic daylight metrics (e.g. daylight autonomy, spatial daylight autonomy, useful daylight illuminance) can be more complex evaluation criteria because they are based on annual daylight illuminance data for a building site. While the daylight factor value depends only on a room geometry, optical properties of surfaces and positioning of daylight obstructions, the dynamic daylight metrics also include an effect of a building location, window orientation or building occupancy pattern. The article deals with a comparison of a daylight evaluation using dynamic and static daylight metrics in the case of buildings whose daylight is obstructed by external barriers.
Název v anglickém jazyce
Comparison between Dynamic and Static Metrics for Daylight Evaluation in the Case of Obstructed Buildings
Popis výsledku anglicky
Daylight in buildings can be evaluated using dynamic and static daylight metrics. The daylight factor is a static daylight metric which evaluates daylight conditions under the overcast sky model according to the International Commission on Illumination. However, the dynamic daylight metrics (e.g. daylight autonomy, spatial daylight autonomy, useful daylight illuminance) can be more complex evaluation criteria because they are based on annual daylight illuminance data for a building site. While the daylight factor value depends only on a room geometry, optical properties of surfaces and positioning of daylight obstructions, the dynamic daylight metrics also include an effect of a building location, window orientation or building occupancy pattern. The article deals with a comparison of a daylight evaluation using dynamic and static daylight metrics in the case of buildings whose daylight is obstructed by external barriers.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1408" target="_blank" >LO1408: AdMaS UP - Pokročilé stavební materiály, konstrukce a technologie</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Buildings and Environment - Energy Performance, Smart Materials and Buildings
ISBN
978-3-0357-1070-0
ISSN
1660-9336
e-ISSN
—
Počet stran výsledku
8
Strana od-do
477-484
Název nakladatele
Trans Tech Publications
Místo vydání
Switzerland
Místo konání akce
Brno
Datum konání akce
22. 9. 2016
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—