Parametric analysis of cooling consumption in high-rise building
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F16%3APU122085" target="_blank" >RIV/00216305:26110/16:PU122085 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Parametric analysis of cooling consumption in high-rise building
Popis výsledku v původním jazyce
This case study is aimed at parametrical analysis of cooling consumption in the high-rise building. Impact of several parameters such as indoor air temperature, inlet air temperature and using heat recovery of ventilation system in summer period is examined. These simulations are performed in Danish software BSim 2002. Results show that impact of the set indoor air temperature on the total cooling consumption is significant. The total costs are lower when the inlet air temperature is higher that the set indoor air temperature. Using of the heat recovery of ventilation system in summer period also reduces cooling consumption. The heat recovery is in operation only when the operative temperature in the zone is at least 2.0 K lower than the outdoor temperature. It is not useful in the other cases.
Název v anglickém jazyce
Parametric analysis of cooling consumption in high-rise building
Popis výsledku anglicky
This case study is aimed at parametrical analysis of cooling consumption in the high-rise building. Impact of several parameters such as indoor air temperature, inlet air temperature and using heat recovery of ventilation system in summer period is examined. These simulations are performed in Danish software BSim 2002. Results show that impact of the set indoor air temperature on the total cooling consumption is significant. The total costs are lower when the inlet air temperature is higher that the set indoor air temperature. Using of the heat recovery of ventilation system in summer period also reduces cooling consumption. The heat recovery is in operation only when the operative temperature in the zone is at least 2.0 K lower than the outdoor temperature. It is not useful in the other cases.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1408" target="_blank" >LO1408: AdMaS UP - Pokročilé stavební materiály, konstrukce a technologie</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
INDOOR CLIMATE OF BUILDINGS 2016
ISBN
978-80-89878-04-8
ISSN
—
e-ISSN
—
Počet stran výsledku
303
Strana od-do
189-195
Název nakladatele
Slovak Society of Environmental Technology
Místo vydání
Bratislava
Místo konání akce
Štrbské Pleso
Datum konání akce
27. 11. 2016
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—