Thermal Insulation - Using and Testing of Materials in Composite Insulation Systems for Residential Buildings
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F16%3APU122806" target="_blank" >RIV/00216305:26110/16:PU122806 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.itpb.eu/index.php/ct-menu-item-3/14-engineering/340-10-cislo-46-clanok" target="_blank" >http://www.itpb.eu/index.php/ct-menu-item-3/14-engineering/340-10-cislo-46-clanok</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Thermal Insulation - Using and Testing of Materials in Composite Insulation Systems for Residential Buildings
Popis výsledku v původním jazyce
Energy saving is currently a frequently discussed issue which is investigated not only in terms of building operation but also with regard to the construction of structures. One of the evaluated parameters is the thermal transmittance through the insulation envelope of the building, the U-value. In the Czech Republic, one of the most widely-used measures for ensuring a building envelope has the correct parameters is the installation of a contact-based External Thermal Insulation Composite System (ETICS). Its most important parts are the thermal insulation layer and the base layer. These two layers determine the basic parameters of the whole system, i.e. the U-value (thermal insulation) and the lifespan and resistance (base layer). This article focuses on the options available for the use of different types of thermal insulation in insulation systems and also for the subsequent installation and testing of the base layer with regard to the selected thermal insulation.
Název v anglickém jazyce
Thermal Insulation - Using and Testing of Materials in Composite Insulation Systems for Residential Buildings
Popis výsledku anglicky
Energy saving is currently a frequently discussed issue which is investigated not only in terms of building operation but also with regard to the construction of structures. One of the evaluated parameters is the thermal transmittance through the insulation envelope of the building, the U-value. In the Czech Republic, one of the most widely-used measures for ensuring a building envelope has the correct parameters is the installation of a contact-based External Thermal Insulation Composite System (ETICS). Its most important parts are the thermal insulation layer and the base layer. These two layers determine the basic parameters of the whole system, i.e. the U-value (thermal insulation) and the lifespan and resistance (base layer). This article focuses on the options available for the use of different types of thermal insulation in insulation systems and also for the subsequent installation and testing of the base layer with regard to the selected thermal insulation.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
International journal of interdisciplinarity in theory and practice
ISSN
2344-2409
e-ISSN
—
Svazek periodika
2016
Číslo periodika v rámci svazku
10
Stát vydavatele periodika
RO - Rumunsko
Počet stran výsledku
7
Strana od-do
246-252
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—