Double Windows in Heritage Listed Buildings
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F16%3APU123157" target="_blank" >RIV/00216305:26110/16:PU123157 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.scientific.net/AMM.861.247" target="_blank" >https://www.scientific.net/AMM.861.247</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.4028/www.scientific.net/AMM.861.247" target="_blank" >10.4028/www.scientific.net/AMM.861.247</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Double Windows in Heritage Listed Buildings
Popis výsledku v původním jazyce
Heritage listed buildings, or their parts, are subject to the decisions of state authorities in the field of heritage preservation. When windows are reconstructed, the requirements concerning the new design are most often based on the original appearance of the windows. In the case of double windows - the traditional style with space and reveal in between - the outer window is installed with insulated glazing while the inner window has a simple glazing, in order to meet the conditions of thermal related technical standards. For this reason, the contact between the window frame and the reveal must be tight with very low air permeability. The article presents the measurements of surface temperatures of both of the window parts and explores the issue of thermal humidity condition in the area between the windows.
Název v anglickém jazyce
Double Windows in Heritage Listed Buildings
Popis výsledku anglicky
Heritage listed buildings, or their parts, are subject to the decisions of state authorities in the field of heritage preservation. When windows are reconstructed, the requirements concerning the new design are most often based on the original appearance of the windows. In the case of double windows - the traditional style with space and reveal in between - the outer window is installed with insulated glazing while the inner window has a simple glazing, in order to meet the conditions of thermal related technical standards. For this reason, the contact between the window frame and the reveal must be tight with very low air permeability. The article presents the measurements of surface temperatures of both of the window parts and explores the issue of thermal humidity condition in the area between the windows.
Klasifikace
Druh
J<sub>ost</sub> - Ostatní články v recenzovaných periodicích
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Applied Mechanics and Materials
ISSN
1662-7482
e-ISSN
—
Svazek periodika
Vol. 861
Číslo periodika v rámci svazku
Vol. 861
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
7
Strana od-do
247-254
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—