Popis výsledku v původním jazyce
The determination of reinforcement corrosion using electrical resistance method of embedded in the concrete beams in laboratory conditions has been described in this paper. For comparison, the achieved data from non-destructive measurements were compared to data from subsequent destructive tests when weight losses were recorded for each steel bars after their exposure time. Laboratory measurements of reinforcements were realized particularly for verification whether the electrical resistance method could be suitable for in-situ corrosion evaluation process. The next part of research was focused on corrosion simulation of steel reinforcement in reinforced concrete. The effect of corrosion was simulated by the nonlinear numerical analysis with the program ATENA 3D using corrosion rate data from laboratory test.
Název v anglickém jazyce
Corrosion Determination of Reinforcement Using Electrical Resistance Method
Popis výsledku anglicky
The determination of reinforcement corrosion using electrical resistance method of embedded in the concrete beams in laboratory conditions has been described in this paper. For comparison, the achieved data from non-destructive measurements were compared to data from subsequent destructive tests when weight losses were recorded for each steel bars after their exposure time. Laboratory measurements of reinforcements were realized particularly for verification whether the electrical resistance method could be suitable for in-situ corrosion evaluation process. The next part of research was focused on corrosion simulation of steel reinforcement in reinforced concrete. The effect of corrosion was simulated by the nonlinear numerical analysis with the program ATENA 3D using corrosion rate data from laboratory test.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/GA14-25504S" target="_blank" >GA14-25504S: Výzkum chování kompozitů na bázi anorganických matric v extrémních podmínkách</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Materiali in tehnologije
ISSN
1580-2949
e-ISSN
1580-3414
Svazek periodika
51
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
SI - Slovinská republika
Počet stran výsledku
9
Strana od-do
85-93
Kód UT WoS článku
000396592900014
EID výsledku v databázi Scopus
2-s2.0-85027435201