Long-action of additional horizontal prestressing on masonry
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F17%3APU124168" target="_blank" >RIV/00216305:26110/17:PU124168 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.scopus.com/record/display.uri?eid=2-s2.0-85029692186&origin=resultslist&sort=plf-f&src=s&st1=Long-action+of+Additional+Horizontal+Prestressing+on+Masonry&st2=&sid=467aeb58b84e0afbe736906c86870d5b&sot=b&sdt=b&sl=75&s=TITLE-ABS-KEY%28Long-actio" target="_blank" >https://www.scopus.com/record/display.uri?eid=2-s2.0-85029692186&origin=resultslist&sort=plf-f&src=s&st1=Long-action+of+Additional+Horizontal+Prestressing+on+Masonry&st2=&sid=467aeb58b84e0afbe736906c86870d5b&sot=b&sdt=b&sl=75&s=TITLE-ABS-KEY%28Long-actio</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.proeng.2017.04.525" target="_blank" >10.1016/j.proeng.2017.04.525</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Long-action of additional horizontal prestressing on masonry
Popis výsledku v původním jazyce
This article is focused on verifying behaviour of a brick masonry which was horizontally post-tensioned. An experimental model of three walls has been built for the measurement. The model is in scale 1:1 and represents a part of a real structure. Longitudinal strain of brick walls has been measured by wire strain gauges in important places. Surrounding temperature and temperature inside the walls were also recorded. Results of the experiment have been continuously evaluated and compared with the simplified numerical models. Right now we have a better picture of actual behaviour of the brick masonry wall which was horizontally prestressed and we are able to design appropriate restoration works for historical buildings.
Název v anglickém jazyce
Long-action of additional horizontal prestressing on masonry
Popis výsledku anglicky
This article is focused on verifying behaviour of a brick masonry which was horizontally post-tensioned. An experimental model of three walls has been built for the measurement. The model is in scale 1:1 and represents a part of a real structure. Longitudinal strain of brick walls has been measured by wire strain gauges in important places. Surrounding temperature and temperature inside the walls were also recorded. Results of the experiment have been continuously evaluated and compared with the simplified numerical models. Right now we have a better picture of actual behaviour of the brick masonry wall which was horizontally prestressed and we are able to design appropriate restoration works for historical buildings.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1408" target="_blank" >LO1408: AdMaS UP - Pokročilé stavební materiály, konstrukce a technologie</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Procedia Engineering
ISSN
1877-7058
e-ISSN
—
Svazek periodika
neuveden
Číslo periodika v rámci svazku
195
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
6
Strana od-do
67-72
Kód UT WoS článku
000419273400010
EID výsledku v databázi Scopus
2-s2.0-85029692186