Experimental setups for the measurement of the rotational restraint provided to cold-formed Z-purlins by sandwich panels
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F17%3APU124704" target="_blank" >RIV/00216305:26110/17:PU124704 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1002/cepa.211" target="_blank" >http://dx.doi.org/10.1002/cepa.211</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/cepa.211" target="_blank" >10.1002/cepa.211</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Experimental setups for the measurement of the rotational restraint provided to cold-formed Z-purlins by sandwich panels
Popis výsledku v původním jazyce
Sandwich panels supported by purlins are widely used as the main load bearing part of roof systems of the steel buildings. Sandwich panels provide lateral and rotational restraint to purlins which positively influences their resistance. Lateral restraint given by sandwich panels is equal for both downward load and uplift load applied on the panel’s surface, though the rotational restraint may have different character. The uplift load reduces contact area between the panels and purlins which can result in smaller restraint value. ECCS Publication No 135/CIB Publication 379 states, the rotational restraint for uplift shall be determined by tests with recommended setup, otherwise zero value has to be considered. The recommended setup, originally developed by Joachim Lindner, was also used for the large EASIE testing program, which was the base of the aforementioned recommendation. Test setup from EN 1993-1-3, originally developed by Teoman Peköz for tests with cold-formed purlins and corrugated sheeting, has been considered as inappropriate for sandwich panels because it does not consider effects from transverse load. During the EASIE test program only hot-rolled purlins were tested and therefore evaluation did not take into account section distortion (which is negligible for hot-rolled sections). Application of the test results for cold-formed purlins and conclusion related to the rotational restraint under uplift load therefore requires re-confirmation by tests with cold-formed purlins. Experimental research to determine the rotational restraint given to cold-formed Z purlins by sandwich panels was performed at Brno University of Technology (BUT) in cooperation with Astron Buildings S.A. (Astron). Tested were sandwich panels with direct fastening and hidden fastening, with PUR/PIR and mineral wool core. ECCS/CIB test setup with application of a torsional moment and a modified setup with application of a direct force were used. Several tests were additionally done w
Název v anglickém jazyce
Experimental setups for the measurement of the rotational restraint provided to cold-formed Z-purlins by sandwich panels
Popis výsledku anglicky
Sandwich panels supported by purlins are widely used as the main load bearing part of roof systems of the steel buildings. Sandwich panels provide lateral and rotational restraint to purlins which positively influences their resistance. Lateral restraint given by sandwich panels is equal for both downward load and uplift load applied on the panel’s surface, though the rotational restraint may have different character. The uplift load reduces contact area between the panels and purlins which can result in smaller restraint value. ECCS Publication No 135/CIB Publication 379 states, the rotational restraint for uplift shall be determined by tests with recommended setup, otherwise zero value has to be considered. The recommended setup, originally developed by Joachim Lindner, was also used for the large EASIE testing program, which was the base of the aforementioned recommendation. Test setup from EN 1993-1-3, originally developed by Teoman Peköz for tests with cold-formed purlins and corrugated sheeting, has been considered as inappropriate for sandwich panels because it does not consider effects from transverse load. During the EASIE test program only hot-rolled purlins were tested and therefore evaluation did not take into account section distortion (which is negligible for hot-rolled sections). Application of the test results for cold-formed purlins and conclusion related to the rotational restraint under uplift load therefore requires re-confirmation by tests with cold-formed purlins. Experimental research to determine the rotational restraint given to cold-formed Z purlins by sandwich panels was performed at Brno University of Technology (BUT) in cooperation with Astron Buildings S.A. (Astron). Tested were sandwich panels with direct fastening and hidden fastening, with PUR/PIR and mineral wool core. ECCS/CIB test setup with application of a torsional moment and a modified setup with application of a direct force were used. Several tests were additionally done w
Klasifikace
Druh
J<sub>ost</sub> - Ostatní články v recenzovaných periodicích
CEP obor
—
OECD FORD obor
20102 - Construction engineering, Municipal and structural engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
ce/papers
ISSN
2509-7075
e-ISSN
—
Svazek periodika
1
Číslo periodika v rámci svazku
2-3
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
10
Strana od-do
1677-1686
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—