Evaluation of groundwater contamination in former military airport area
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F18%3APU128388" target="_blank" >RIV/00216305:26110/18:PU128388 - isvavai.cz</a>
Výsledek na webu
<a href="http://casopis-gradjevinar.hr/archive/article/2161" target="_blank" >http://casopis-gradjevinar.hr/archive/article/2161</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.14256/JCE.2161.2017" target="_blank" >10.14256/JCE.2161.2017</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Evaluation of groundwater contamination in former military airport area
Popis výsledku v původním jazyce
The analysis of groundwater contamination at the former military airport, due to fuel tanks leakage and other accidental spills, mainly involving polycyclic aromatic hydrocarbons (PAH), is presented in the paper. It was observed by modelling that, after termination of pumping, the contaminant by-passes the slurry wall around its edges and proceeds towards the withdrawal area. The modelling showed that the water contamination hazard is quite low, which is mainly due to pollutant deterioration (decay) and sorption. Systematic and long-term groundwater quality monitoring is recommended once pumping at the barrier is stopped.
Název v anglickém jazyce
Evaluation of groundwater contamination in former military airport area
Popis výsledku anglicky
The analysis of groundwater contamination at the former military airport, due to fuel tanks leakage and other accidental spills, mainly involving polycyclic aromatic hydrocarbons (PAH), is presented in the paper. It was observed by modelling that, after termination of pumping, the contaminant by-passes the slurry wall around its edges and proceeds towards the withdrawal area. The modelling showed that the water contamination hazard is quite low, which is mainly due to pollutant deterioration (decay) and sorption. Systematic and long-term groundwater quality monitoring is recommended once pumping at the barrier is stopped.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1408" target="_blank" >LO1408: AdMaS UP - Pokročilé stavební materiály, konstrukce a technologie</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
GRADEVINAR
ISSN
0350-2465
e-ISSN
1333-9095
Svazek periodika
70
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
HR - Chorvatská republika
Počet stran výsledku
7
Strana od-do
337-343
Kód UT WoS článku
000436487200008
EID výsledku v databázi Scopus
2-s2.0-85048639195