The bond strength by pull-off and direct tensile strength of concrete damaged by elevated temperatures
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F18%3APU128471" target="_blank" >RIV/00216305:26110/18:PU128471 - isvavai.cz</a>
Výsledek na webu
<a href="http://iopscience.iop.org/article/10.1088/1757-899X/385/1/012047" target="_blank" >http://iopscience.iop.org/article/10.1088/1757-899X/385/1/012047</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1757-899X/385/1/012047" target="_blank" >10.1088/1757-899X/385/1/012047</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The bond strength by pull-off and direct tensile strength of concrete damaged by elevated temperatures
Popis výsledku v původním jazyce
This paper presents the results of an experimental study of selected characteristics of concrete following its exposure to high temperatures. The monitored parameter was the influence of high temperatures on the bond strength and tensile strength of concrete. The bond strength was tested by a pull-off test, the tensile strength was determined as the direct tensile strength. Experimental concrete panels of 2300 x 1300 x 150 mm were exposed to high temperatures (corresponding to the temperatures in a normal fire) using a fire test furnace at the AdMaS Science Centre of the Faculty of Civil Engineering, Brno University of Technology. The direct tensile strength test was performed on cylinders (diameter of 100 mm and length of 100 mm) made from core samples taken from the panel. The pull-off test was performed on the surface exposed to high temperatures. The results of the experiment show a significant influence of high temperatures on the examined characteristics, and both characteristics were found to significantly decrease with a growing thermal load.
Název v anglickém jazyce
The bond strength by pull-off and direct tensile strength of concrete damaged by elevated temperatures
Popis výsledku anglicky
This paper presents the results of an experimental study of selected characteristics of concrete following its exposure to high temperatures. The monitored parameter was the influence of high temperatures on the bond strength and tensile strength of concrete. The bond strength was tested by a pull-off test, the tensile strength was determined as the direct tensile strength. Experimental concrete panels of 2300 x 1300 x 150 mm were exposed to high temperatures (corresponding to the temperatures in a normal fire) using a fire test furnace at the AdMaS Science Centre of the Faculty of Civil Engineering, Brno University of Technology. The direct tensile strength test was performed on cylinders (diameter of 100 mm and length of 100 mm) made from core samples taken from the panel. The pull-off test was performed on the surface exposed to high temperatures. The results of the experiment show a significant influence of high temperatures on the examined characteristics, and both characteristics were found to significantly decrease with a growing thermal load.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Construmat 2018
ISBN
—
ISSN
1757-8981
e-ISSN
—
Počet stran výsledku
6
Strana od-do
1-6
Název nakladatele
IOP Publishing
Místo vydání
Bristol
Místo konání akce
Herľany
Datum konání akce
13. 6. 2018
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—