Nonlinear Model of an Additional Concrete Head and its Comparison with Long-Term Measurements
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F18%3APU129307" target="_blank" >RIV/00216305:26110/18:PU129307 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.2478/sjce-2018-0014" target="_blank" >http://dx.doi.org/10.2478/sjce-2018-0014</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.2478/sjce-2018-0014" target="_blank" >10.2478/sjce-2018-0014</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Nonlinear Model of an Additional Concrete Head and its Comparison with Long-Term Measurements
Popis výsledku v původním jazyce
An additional concrete head or drop panels are not common solutions for strengthening flat slabs and have not yet been an adequately studied solution in the field of laboratory research. The investigation of drop panels in a laboratory is quite complicated, so that an examination directly at a construction site could be a better solution. Long-term measurement sensors were installed inside a concrete drop panel, which is on the bottom surface of a flat slab. Gauging was performed during various loading situations, including the loading of heavy machines, the ambient temperature load, and a uniformly distributed load. Results from the measurements are given in comparison with analytical models, which have been studied with respect to the influence of shrinkage and the bond-slip behaviour of a reinforcement.
Název v anglickém jazyce
Nonlinear Model of an Additional Concrete Head and its Comparison with Long-Term Measurements
Popis výsledku anglicky
An additional concrete head or drop panels are not common solutions for strengthening flat slabs and have not yet been an adequately studied solution in the field of laboratory research. The investigation of drop panels in a laboratory is quite complicated, so that an examination directly at a construction site could be a better solution. Long-term measurement sensors were installed inside a concrete drop panel, which is on the bottom surface of a flat slab. Gauging was performed during various loading situations, including the loading of heavy machines, the ambient temperature load, and a uniformly distributed load. Results from the measurements are given in comparison with analytical models, which have been studied with respect to the influence of shrinkage and the bond-slip behaviour of a reinforcement.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20102 - Construction engineering, Municipal and structural engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/TH03020446" target="_blank" >TH03020446: Vývoj dispozičně variabilnější panelové soustavy pro bytové domy</a><br>
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Slovak Journal of Civil Emgineering
ISSN
1210-3896
e-ISSN
—
Svazek periodika
26
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
SK - Slovenská republika
Počet stran výsledku
10
Strana od-do
1-10
Kód UT WoS článku
000447696600001