Test of the tensile load capacity of a timber structure joint with an inserted nail plate
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F19%3APU132366" target="_blank" >RIV/00216305:26110/19:PU132366 - isvavai.cz</a>
Výsledek na webu
<a href="https://iopscience.iop.org/article/10.1088/1757-899X/549/1/012035/pdf" target="_blank" >https://iopscience.iop.org/article/10.1088/1757-899X/549/1/012035/pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1757-899X/549/1/012035" target="_blank" >10.1088/1757-899X/549/1/012035</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Test of the tensile load capacity of a timber structure joint with an inserted nail plate
Popis výsledku v původním jazyce
The aim of this paper was to determine the axial tensile load capacity of timber structure elements with inserted metal plates with welded nails. The tests were performed on three specimens in the laboratory of the AdMaS centre of the Faculty of Civil Engineering, Brno University of Technology. The tensile force was applied on the specimen by increasing the force up to the specimen failure. The inductive displacement transducers continuously measured the displacement of the inserted joint plates with regard to timber prisms. The tensile load-bearing capacity of the tested joint was determined at 205.0 kN. Due to the advantages, the tested joints with inserted nail plates seem to be appropriate for joining suitable timber elements
Název v anglickém jazyce
Test of the tensile load capacity of a timber structure joint with an inserted nail plate
Popis výsledku anglicky
The aim of this paper was to determine the axial tensile load capacity of timber structure elements with inserted metal plates with welded nails. The tests were performed on three specimens in the laboratory of the AdMaS centre of the Faculty of Civil Engineering, Brno University of Technology. The tensile force was applied on the specimen by increasing the force up to the specimen failure. The inductive displacement transducers continuously measured the displacement of the inserted joint plates with regard to timber prisms. The tensile load-bearing capacity of the tested joint was determined at 205.0 kN. Due to the advantages, the tested joints with inserted nail plates seem to be appropriate for joining suitable timber elements
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1408" target="_blank" >LO1408: AdMaS UP - Pokročilé stavební materiály, konstrukce a technologie</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
IOP Conference Series: Materials Science and Engineering
ISBN
—
ISSN
1757-8981
e-ISSN
—
Počet stran výsledku
6
Strana od-do
1-6
Název nakladatele
IOP Publishing
Místo vydání
Bristol
Místo konání akce
Zuberec
Datum konání akce
29. 5. 2019
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—