Identifying Concrete Resistance to Corrosion by Deionised Water with Aggressive Carbon Dioxide
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F19%3APU132382" target="_blank" >RIV/00216305:26110/19:PU132382 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.scientific.net/SSP.292.34" target="_blank" >https://www.scientific.net/SSP.292.34</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.4028/www.scientific.net/SSP.292.34" target="_blank" >10.4028/www.scientific.net/SSP.292.34</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Identifying Concrete Resistance to Corrosion by Deionised Water with Aggressive Carbon Dioxide
Popis výsledku v původním jazyce
The paper discusses an experimental technique of comparing different concretes in terms of their resistance to leaching corrosion. Specifically, the experiment compared the resistance of three different high-performance concretes exposed to deionised water with aggressive carbon dioxide. To control the duration of the laboratory tests, they were not performed on these particular concretes, but rather on model mortars derived from them; the mortars proved perfectly sufficient to give the desired information. The paper also describes how these mortars were created on the basis of known or assumed concrete formulae. The actual corrosion test was designed as a double-comparative experiment. The paper lists all the basic test results, which confirm the effectiveness of the comparative method – the experiment was successful in drawing clear comparison between the concrete variants.
Název v anglickém jazyce
Identifying Concrete Resistance to Corrosion by Deionised Water with Aggressive Carbon Dioxide
Popis výsledku anglicky
The paper discusses an experimental technique of comparing different concretes in terms of their resistance to leaching corrosion. Specifically, the experiment compared the resistance of three different high-performance concretes exposed to deionised water with aggressive carbon dioxide. To control the duration of the laboratory tests, they were not performed on these particular concretes, but rather on model mortars derived from them; the mortars proved perfectly sufficient to give the desired information. The paper also describes how these mortars were created on the basis of known or assumed concrete formulae. The actual corrosion test was designed as a double-comparative experiment. The paper lists all the basic test results, which confirm the effectiveness of the comparative method – the experiment was successful in drawing clear comparison between the concrete variants.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Solid State Phenomena: 25th Concrete Days 2018
ISBN
978-3-0357-1459-3
ISSN
1662-9779
e-ISSN
—
Počet stran výsledku
6
Strana od-do
34-39
Název nakladatele
Trans Tech Publications
Místo vydání
Switzerland
Místo konání akce
Praha
Datum konání akce
21. 11. 2018
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—