HYGROTHERMAL ASSESSMENT OF ROOFS WITH ABOVE-RAFTER THERMAL INSULATION IN THE DETAIL OF THE EAVE OVERHANG
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F19%3APU132943" target="_blank" >RIV/00216305:26110/19:PU132943 - isvavai.cz</a>
Výsledek na webu
<a href="https://akademiai.com/doi/10.1556/1848.2019.0005" target="_blank" >https://akademiai.com/doi/10.1556/1848.2019.0005</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1556/1848.2019.0005" target="_blank" >10.1556/1848.2019.0005</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
HYGROTHERMAL ASSESSMENT OF ROOFS WITH ABOVE-RAFTER THERMAL INSULATION IN THE DETAIL OF THE EAVE OVERHANG
Popis výsledku v původním jazyce
This paper is focused on hygrothermal assessment of the eave overhang detail in above-rafter placed thermal insulation roof system. Results of the long-term measurement of this detail performed on a real building as well as the testing of the measuring method are presented in this paper. Within this measurement the moisture of wooden elements performing an eave overhang of the roof was monitored primarily in order to verify their long-term functionality. In addition the temperature and relative humidity in the roof structure were measured as well. As part of this measurement, various design variants of above mentioned detail in combination with different compositions of the roof structure were compared. The long-term functionality of the assessed details is evaluated in the conclusion of this paper, taking into account especially hygrothermal status of wooden element, which is associated with threats of infestation of these elements by wood decaying fungi or insects.
Název v anglickém jazyce
HYGROTHERMAL ASSESSMENT OF ROOFS WITH ABOVE-RAFTER THERMAL INSULATION IN THE DETAIL OF THE EAVE OVERHANG
Popis výsledku anglicky
This paper is focused on hygrothermal assessment of the eave overhang detail in above-rafter placed thermal insulation roof system. Results of the long-term measurement of this detail performed on a real building as well as the testing of the measuring method are presented in this paper. Within this measurement the moisture of wooden elements performing an eave overhang of the roof was monitored primarily in order to verify their long-term functionality. In addition the temperature and relative humidity in the roof structure were measured as well. As part of this measurement, various design variants of above mentioned detail in combination with different compositions of the roof structure were compared. The long-term functionality of the assessed details is evaluated in the conclusion of this paper, taking into account especially hygrothermal status of wooden element, which is associated with threats of infestation of these elements by wood decaying fungi or insects.
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1408" target="_blank" >LO1408: AdMaS UP - Pokročilé stavební materiály, konstrukce a technologie</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Int. Rev. Appl. Sci. Eng
ISSN
2062-0810
e-ISSN
—
Svazek periodika
10
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
HU - Maďarsko
Počet stran výsledku
6
Strana od-do
29-34
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-85068913138