The determination of measurement errors in impedance spectroscopy
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F19%3APU133555" target="_blank" >RIV/00216305:26110/19:PU133555 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.researchgate.net/publication/335171194_The_determination_of_measurement_errors_in_impedance_spectroscopy" target="_blank" >https://www.researchgate.net/publication/335171194_The_determination_of_measurement_errors_in_impedance_spectroscopy</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1757-899X/583/1/012030" target="_blank" >10.1088/1757-899X/583/1/012030</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The determination of measurement errors in impedance spectroscopy
Popis výsledku v původním jazyce
The paper deals with the methodology, quantification and comparison of measurement deviations for two types of the ceramic shard. The ceramic material has better polarization properties than concrete material. For impedance measurement the ceramic shard is more appropriate. The IS method diagnostics based on processing of measured data which aims evaluating the absolute error and the relative error (deviation) of the loss factor values. Results show the spectrum parts which are useful in the lower frequency range only. When Agilent 33220A and Agilent 54645A are used to carry out the IS, the most important factor from the viewpoint of the tgδ(f) determination accuracy is the accuracy of the phase shift between the excitation signal and that at the measured system output. Other factors are the measurement accuracy of the electric capacity and resistance of the oscilloscope input channel.
Název v anglickém jazyce
The determination of measurement errors in impedance spectroscopy
Popis výsledku anglicky
The paper deals with the methodology, quantification and comparison of measurement deviations for two types of the ceramic shard. The ceramic material has better polarization properties than concrete material. For impedance measurement the ceramic shard is more appropriate. The IS method diagnostics based on processing of measured data which aims evaluating the absolute error and the relative error (deviation) of the loss factor values. Results show the spectrum parts which are useful in the lower frequency range only. When Agilent 33220A and Agilent 54645A are used to carry out the IS, the most important factor from the viewpoint of the tgδ(f) determination accuracy is the accuracy of the phase shift between the excitation signal and that at the measured system output. Other factors are the measurement accuracy of the electric capacity and resistance of the oscilloscope input channel.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
22st International Conference on Building Materials, Products and Technologies
ISBN
—
ISSN
1757-8981
e-ISSN
—
Počet stran výsledku
5
Strana od-do
1-5
Název nakladatele
Institute of Physics Publishing
Místo vydání
United Kingdom
Místo konání akce
Lednice
Datum konání akce
4. 6. 2019
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—