Flow erosion resistance of concrete-interaction of high-speed water jet and concrete
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F19%3APU135669" target="_blank" >RIV/00216305:26110/19:PU135669 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.scopus.com/record/display.uri?eid=2-s2.0-85072941493&origin=resultslist&sort=plf-f&src=s&st1=bodnarova+l.&st2=&sid=c8e5e9630d413d5389642b15ad841f78&sot=b&sdt=b&sl=25&s=AUTHOR-NAME%28bodnarova+l.%29&relpos=2&citeCnt=0&searchTerm=" target="_blank" >https://www.scopus.com/record/display.uri?eid=2-s2.0-85072941493&origin=resultslist&sort=plf-f&src=s&st1=bodnarova+l.&st2=&sid=c8e5e9630d413d5389642b15ad841f78&sot=b&sdt=b&sl=25&s=AUTHOR-NAME%28bodnarova+l.%29&relpos=2&citeCnt=0&searchTerm=</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.4028/www.scientific.net/SSP.296.215" target="_blank" >10.4028/www.scientific.net/SSP.296.215</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Flow erosion resistance of concrete-interaction of high-speed water jet and concrete
Popis výsledku v původním jazyce
In the paper, the resistance of concrete to the erosive effect of water from a water jet was monitored. The tests were performed on concrete without the addition of fibres and on concrete with the addition of polypropylene fibres and steel fibres. The water flow hit the concrete surface at an angle of 90°. The flow rate was 1.1 l/min and the water pressure was 80 MPa. After blasting the concrete with water jet, no cracks in the concrete were observed and the intended rugged surface relief was created. Steel fibres remained firmly anchored into the cement matrix.
Název v anglickém jazyce
Flow erosion resistance of concrete-interaction of high-speed water jet and concrete
Popis výsledku anglicky
In the paper, the resistance of concrete to the erosive effect of water from a water jet was monitored. The tests were performed on concrete without the addition of fibres and on concrete with the addition of polypropylene fibres and steel fibres. The water flow hit the concrete surface at an angle of 90°. The flow rate was 1.1 l/min and the water pressure was 80 MPa. After blasting the concrete with water jet, no cracks in the concrete were observed and the intended rugged surface relief was created. Steel fibres remained firmly anchored into the cement matrix.
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
20102 - Construction engineering, Municipal and structural engineering
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Solid State Phenomena
ISSN
1662-9779
e-ISSN
—
Svazek periodika
296
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
6
Strana od-do
215-220
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-85072941493