Non linear FEM analysis of composite concrete slab exposed to extreme thermal load
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F20%3APU135379" target="_blank" >RIV/00216305:26110/20:PU135379 - isvavai.cz</a>
Výsledek na webu
<a href="https://aip.scitation.org/doi/abs/10.1063/5.0026880?journalCode=apc" target="_blank" >https://aip.scitation.org/doi/abs/10.1063/5.0026880?journalCode=apc</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1063/5.0026880" target="_blank" >10.1063/5.0026880</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Non linear FEM analysis of composite concrete slab exposed to extreme thermal load
Popis výsledku v původním jazyce
Numerical approach using the FEM has been used to model the behavior of a composite concrete−steel structure exposed to fire. Geometry of the structure is considered as a simply supported beam, which supports the slab. Fire load has been defined by a nominal standard ISO 834 fire curve. Fire resistant gypsum board protection of the structure is considered during the thermal analysis. Both, thermal and structural response are obtained using a FEM software ANSYS. Temperature-dependent nonlinear thermal and mechanical properties of concrete, reinforcement and steel are adopted in accordance with Eurocode standards. Nonlinear material model Menetrey-Willam with compression hardening and softening and tension softening features has been used to describe the behavior of concrete elements.
Název v anglickém jazyce
Non linear FEM analysis of composite concrete slab exposed to extreme thermal load
Popis výsledku anglicky
Numerical approach using the FEM has been used to model the behavior of a composite concrete−steel structure exposed to fire. Geometry of the structure is considered as a simply supported beam, which supports the slab. Fire load has been defined by a nominal standard ISO 834 fire curve. Fire resistant gypsum board protection of the structure is considered during the thermal analysis. Both, thermal and structural response are obtained using a FEM software ANSYS. Temperature-dependent nonlinear thermal and mechanical properties of concrete, reinforcement and steel are adopted in accordance with Eurocode standards. Nonlinear material model Menetrey-Willam with compression hardening and softening and tension softening features has been used to describe the behavior of concrete elements.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/GA17-23578S" target="_blank" >GA17-23578S: Identifikace míry poškození vyztuženého betonu při extrémním zatížení</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
17th International Conference of Numerical Analysis and Applied Mathematics (ICNAAM 2019)
ISBN
978-0-7354-4025-8
ISSN
0094-243X
e-ISSN
—
Počet stran výsledku
4
Strana od-do
1-4
Název nakladatele
American Institute of Physics Inc.
Místo vydání
neuveden
Místo konání akce
hotel Sheraton, Ixia, Rhodos
Datum konání akce
23. 9. 2019
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000636709500300