Evaluation of Aggressive Chemicals Effect on CIPP Liners
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F20%3APU137527" target="_blank" >RIV/00216305:26110/20:PU137527 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.scientific.net/KEM.868.92" target="_blank" >https://www.scientific.net/KEM.868.92</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.4028/www.scientific.net/KEM.868.92" target="_blank" >10.4028/www.scientific.net/KEM.868.92</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Evaluation of Aggressive Chemicals Effect on CIPP Liners
Popis výsledku v původním jazyce
CIPP renovation methods are often used for renovation of sewers and water mains. They can also be used for renovation of gas and product pipelines. However, the presence of chemicals in these pipelines cannot be excluded. For this reason, the ability of CIPP liners to resist chemicals should be examined. This paper deals with problematics of influence of chemicals (acids and bases) on CIPP liners. Visual changes can be observed using an optical microscope. Structural changes are evident from the results of short-term bending tests. During the visual observation, no visible changes in the structure of the samples were found. Exposure of the samples to the 20% hydrochloric acid caused damage of the polyurethane membrane. The polypropylene membrane remained unchanged. The decrease in flexural modulus was most noticeable with samples stored in 10% ammonium hydroxide.
Název v anglickém jazyce
Evaluation of Aggressive Chemicals Effect on CIPP Liners
Popis výsledku anglicky
CIPP renovation methods are often used for renovation of sewers and water mains. They can also be used for renovation of gas and product pipelines. However, the presence of chemicals in these pipelines cannot be excluded. For this reason, the ability of CIPP liners to resist chemicals should be examined. This paper deals with problematics of influence of chemicals (acids and bases) on CIPP liners. Visual changes can be observed using an optical microscope. Structural changes are evident from the results of short-term bending tests. During the visual observation, no visible changes in the structure of the samples were found. Exposure of the samples to the 20% hydrochloric acid caused damage of the polyurethane membrane. The polypropylene membrane remained unchanged. The decrease in flexural modulus was most noticeable with samples stored in 10% ammonium hydroxide.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20102 - Construction engineering, Municipal and structural engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Rehabilitation and Reconstruction of Buildings III
ISBN
9783035736533
ISSN
1013-9826
e-ISSN
—
Počet stran výsledku
6
Strana od-do
92-97
Název nakladatele
Trans Tech Publications Ltd.
Místo vydání
Switzerland
Místo konání akce
Prague
Datum konání akce
28. 11. 2019
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—