Reduction of Light Transmission by Glazing with Atmospheric Pollutants
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F20%3APU140403" target="_blank" >RIV/00216305:26110/20:PU140403 - isvavai.cz</a>
Výsledek na webu
<a href="https://iopscience.iop.org/article/10.1088/1757-899X/728/1/012018/pdf" target="_blank" >https://iopscience.iop.org/article/10.1088/1757-899X/728/1/012018/pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1757-899X/728/1/012018" target="_blank" >10.1088/1757-899X/728/1/012018</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Reduction of Light Transmission by Glazing with Atmospheric Pollutants
Popis výsledku v původním jazyce
Daylight has been used for centuries as the main source of light in interiors and has always been an implicit part of architecture ever since buildings exist. Daylight is an irreplaceable environmental factor and is a prerequisite for a healthy stay in buildings. Ensuring daylight access to the interior is a challenge when designing buildings. The aim is to provide enough daylight for the visual work that indoor building users do. The deposition of air pollutants on the glazing can significantly affect the transmission of daylight into buildings located in urban areas. This study shows the impact of air pollution on glazing permeability in three cities in the Czech Republic. The throughput was measured on a total of 9 windows for half a year. Air purity, exposure to rain, the slope of glazing and use of rooms are factors influencing the final permeability of the glazing. Where glazing is exposed to rain, dirt on the outside of the windows tends to accumulate. The final reduction in throughput is usually 4-8%, with some exceptions.
Název v anglickém jazyce
Reduction of Light Transmission by Glazing with Atmospheric Pollutants
Popis výsledku anglicky
Daylight has been used for centuries as the main source of light in interiors and has always been an implicit part of architecture ever since buildings exist. Daylight is an irreplaceable environmental factor and is a prerequisite for a healthy stay in buildings. Ensuring daylight access to the interior is a challenge when designing buildings. The aim is to provide enough daylight for the visual work that indoor building users do. The deposition of air pollutants on the glazing can significantly affect the transmission of daylight into buildings located in urban areas. This study shows the impact of air pollution on glazing permeability in three cities in the Czech Republic. The throughput was measured on a total of 9 windows for half a year. Air purity, exposure to rain, the slope of glazing and use of rooms are factors influencing the final permeability of the glazing. Where glazing is exposed to rain, dirt on the outside of the windows tends to accumulate. The final reduction in throughput is usually 4-8%, with some exceptions.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20103 - Architecture engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
IOP Conf. Series: Materials Science and Engineering
ISBN
—
ISSN
1757-899X
e-ISSN
—
Počet stran výsledku
5
Strana od-do
1-5
Název nakladatele
IOP Publishing
Místo vydání
Neuveden
Místo konání akce
České Budějovice
Datum konání akce
28. 11. 2019
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—