Experimental testing results of a timber structure's fire resistance in a combustion chamber
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F21%3APU143666" target="_blank" >RIV/00216305:26110/21:PU143666 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.scopus.com/record/display.uri?eid=2-s2.0-85141218339&origin=inward&txGid=a43272ce710749bb94bde69e48541bdb" target="_blank" >https://www.scopus.com/record/display.uri?eid=2-s2.0-85141218339&origin=inward&txGid=a43272ce710749bb94bde69e48541bdb</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.4028/p-r5a1b4" target="_blank" >10.4028/p-r5a1b4</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Experimental testing results of a timber structure's fire resistance in a combustion chamber
Popis výsledku v původním jazyce
Timber is one of the most basic building materials. Even if timber has positive technical properties, there are still many limitations to use wooden building elements in the Czech Republic. It’s necessary to fulfil requirements of normative regulations and prove the required properties before using timber structures in buildings. This paper presents the results of laboratory experimental testing on a timber frame structure. The experiment is based on fire resistance testing in the combustion chamber. The article is also focused on the comparison of types of board edge joints and their influence on fire resistance. The measured data are also compared with fire tests according to normative regulations. The tested structure was classified based on the limit states of fire resistance.
Název v anglickém jazyce
Experimental testing results of a timber structure's fire resistance in a combustion chamber
Popis výsledku anglicky
Timber is one of the most basic building materials. Even if timber has positive technical properties, there are still many limitations to use wooden building elements in the Czech Republic. It’s necessary to fulfil requirements of normative regulations and prove the required properties before using timber structures in buildings. This paper presents the results of laboratory experimental testing on a timber frame structure. The experiment is based on fire resistance testing in the combustion chamber. The article is also focused on the comparison of types of board edge joints and their influence on fire resistance. The measured data are also compared with fire tests according to normative regulations. The tested structure was classified based on the limit states of fire resistance.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Key Engineering Materials
ISBN
—
ISSN
1662-9795
e-ISSN
—
Počet stran výsledku
6
Strana od-do
225-230
Název nakladatele
Neuveden
Místo vydání
neuveden
Místo konání akce
Praha
Datum konání akce
11. 11. 2021
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—