Computer simulation of noise of construction machinery operating in parallel
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F21%3APU143674" target="_blank" >RIV/00216305:26110/21:PU143674 - isvavai.cz</a>
Výsledek na webu
<a href="https://iopscience.iop.org/issue/1757-899X/1203/3" target="_blank" >https://iopscience.iop.org/issue/1757-899X/1203/3</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1757-899X/1203/3/032055" target="_blank" >10.1088/1757-899X/1203/3/032055</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Computer simulation of noise of construction machinery operating in parallel
Popis výsledku v původním jazyce
Prolonged, repeated or very intense noise exposure can damage human health. To reduce any dangerous effects of noise on human health, policies and restrictions are enshrined in national law and legislative regulations. In the Czech Republic, this issue is subject to the Ministry of Health. In other states it can be the Ministry of Health or more often the Ministry of the Environment. The protection of human health against noise and vibration is enshrined in Act No. 258/2000 Coll., on Protection of Public Health, specifically in §§ 30-34 of this Act. Other restrictions are described in Act No. 309/2006 Coll., which regulates other requirements for safety and health protection at work in labour relations and on ensuring safety and health protection in activities or the provision of services outside of labour relations. Furthermore, hygienic limits for workplaces, protected indoor areas of buildings and protected outdoor areas are set in the new Regulation of the Government of the Czech Republic, No. 272/2011 Coll. as amended. This Regulation also sets limits for construction noise. They set limitations in so-called outdoor protected areas and the so-called outdoor protected areas of buildings. The hygienic limit of the equivalent sound pressure level A for noise from construction activities is set here by adding a correction of 5dB or 15dB according to the type of protected space to the basic value of the equivalent sound pressure level A 50dB. This limit must be adhered to. For buildings nearby, the term „protected facades“ is used, i.e. „protected façades“ include the nearest buildings that are inhabited and their occupants could be exposed to noise for a long period of time. We can measure the intensity of noise in these places if we have a "sound level meter". Predicting the intensity of noise and its longevity for future construction is more challenging. The computational evaluation of the noise load of the outdoor area of the monitored territory is based on the
Název v anglickém jazyce
Computer simulation of noise of construction machinery operating in parallel
Popis výsledku anglicky
Prolonged, repeated or very intense noise exposure can damage human health. To reduce any dangerous effects of noise on human health, policies and restrictions are enshrined in national law and legislative regulations. In the Czech Republic, this issue is subject to the Ministry of Health. In other states it can be the Ministry of Health or more often the Ministry of the Environment. The protection of human health against noise and vibration is enshrined in Act No. 258/2000 Coll., on Protection of Public Health, specifically in §§ 30-34 of this Act. Other restrictions are described in Act No. 309/2006 Coll., which regulates other requirements for safety and health protection at work in labour relations and on ensuring safety and health protection in activities or the provision of services outside of labour relations. Furthermore, hygienic limits for workplaces, protected indoor areas of buildings and protected outdoor areas are set in the new Regulation of the Government of the Czech Republic, No. 272/2011 Coll. as amended. This Regulation also sets limits for construction noise. They set limitations in so-called outdoor protected areas and the so-called outdoor protected areas of buildings. The hygienic limit of the equivalent sound pressure level A for noise from construction activities is set here by adding a correction of 5dB or 15dB according to the type of protected space to the basic value of the equivalent sound pressure level A 50dB. This limit must be adhered to. For buildings nearby, the term „protected facades“ is used, i.e. „protected façades“ include the nearest buildings that are inhabited and their occupants could be exposed to noise for a long period of time. We can measure the intensity of noise in these places if we have a "sound level meter". Predicting the intensity of noise and its longevity for future construction is more challenging. The computational evaluation of the noise load of the outdoor area of the monitored territory is based on the
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Abstract Collection of WMCAUS 2021 - 6th World Multidisciplinary Civil Engineering-Architecture-Urban Planning Symposium
ISBN
978-80-553-1488-4
ISSN
1757-899X
e-ISSN
—
Počet stran výsledku
10
Strana od-do
0-10
Název nakladatele
IOP Publishing
Místo vydání
neuveden
Místo konání akce
Štrbské pleso
Datum konání akce
9. 11. 2016
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—