Influence of test parameters on the interlaminar shear strength of FRP bars
Popis výsledku v původním jazyce
At present, the interlaminar shear test is increasingly used as a supplementary test to determine the mechanical characteristics of FRP bars. This is mainly due to its simplicity and its ability to quantify the properties of the fibre/matrix interface. These tests are performed according to ASTM D4475. However, there are several parameters in ASTM D4475 that are not directly specified. Due to this, studies that use such tests feature a variety of different boundary conditions and, consequently, suffer from limited comparability. Furthermore, no study is available in which the effects of changes in selected parameters are comprehensively determined. This paper presents an experimental study that investigated the capabilities and limitations of the short-beam test. In this study a total of 338 specimens from three different manufacturers were tested. The study was focused on the influence of different bar diameters, span-to-diameter ratios and loading speeds. It was found experimentally that the calculated interlaminar shear strength is strongly affected by the applied span-to-diameter ratio. Therefore, the article offers a conversion relationship that takes the span-to-diameter ratio into account. The suitability of the conversion relationship was also verified for alkali-conditioned specimens.
Název v anglickém jazyce
Influence of test parameters on the interlaminar shear strength of FRP bars
Popis výsledku anglicky
At present, the interlaminar shear test is increasingly used as a supplementary test to determine the mechanical characteristics of FRP bars. This is mainly due to its simplicity and its ability to quantify the properties of the fibre/matrix interface. These tests are performed according to ASTM D4475. However, there are several parameters in ASTM D4475 that are not directly specified. Due to this, studies that use such tests feature a variety of different boundary conditions and, consequently, suffer from limited comparability. Furthermore, no study is available in which the effects of changes in selected parameters are comprehensively determined. This paper presents an experimental study that investigated the capabilities and limitations of the short-beam test. In this study a total of 338 specimens from three different manufacturers were tested. The study was focused on the influence of different bar diameters, span-to-diameter ratios and loading speeds. It was found experimentally that the calculated interlaminar shear strength is strongly affected by the applied span-to-diameter ratio. Therefore, the article offers a conversion relationship that takes the span-to-diameter ratio into account. The suitability of the conversion relationship was also verified for alkali-conditioned specimens.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20102 - Construction engineering, Municipal and structural engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/FW01010520" target="_blank" >FW01010520: Vývoj ohýbané kompozitní výztuže pro environmentálně exponované betonové konstrukce</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
COMPOSITE STRUCTURES
ISSN
0263-8223
e-ISSN
1879-1085
Svazek periodika
neuveden
Číslo periodika v rámci svazku
299
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
16
Strana od-do
„“-„“
Kód UT WoS článku
000877976800002
EID výsledku v databázi Scopus
2-s2.0-85135917784