Use of Bended for Reinforcement in the Design of the Slab-Column Connection of a Flat Slab Structure
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F22%3APU146991" target="_blank" >RIV/00216305:26110/22:PU146991 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.scientific.net/SSP.336.151.pdf" target="_blank" >https://www.scientific.net/SSP.336.151.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.4028/p-cr9new" target="_blank" >10.4028/p-cr9new</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Use of Bended for Reinforcement in the Design of the Slab-Column Connection of a Flat Slab Structure
Popis výsledku v původním jazyce
This paper presents the results of an experiment to determine the behaviour of slab-column connection of a flat slab (a column). The main objective is to compare the response of the reinforced specimens with conventional and composite reinforcement and to verify the effectiveness of the stirrups from FRP bars (FRP reinforcement used as shear reinforcement). The test specimen was a square shaped concrete slab in four different designs. The results obtained were compared with the theoretical prediction, quantifying the effect of the FRP reinforcement used on the bearing capacity. Finally, the variations in the prediction according to the different approaches are also highlighted. Comparison of the load capacities of the specimen without and with FRP shear reinforcement led to an increase in the case of stirrups with inclination of 90° by 12 %, reps. stirrups with inclination of 45° by 26 %. The results are influenced by the design of the shear reinforcement.
Název v anglickém jazyce
Use of Bended for Reinforcement in the Design of the Slab-Column Connection of a Flat Slab Structure
Popis výsledku anglicky
This paper presents the results of an experiment to determine the behaviour of slab-column connection of a flat slab (a column). The main objective is to compare the response of the reinforced specimens with conventional and composite reinforcement and to verify the effectiveness of the stirrups from FRP bars (FRP reinforcement used as shear reinforcement). The test specimen was a square shaped concrete slab in four different designs. The results obtained were compared with the theoretical prediction, quantifying the effect of the FRP reinforcement used on the bearing capacity. Finally, the variations in the prediction according to the different approaches are also highlighted. Comparison of the load capacities of the specimen without and with FRP shear reinforcement led to an increase in the case of stirrups with inclination of 90° by 12 %, reps. stirrups with inclination of 45° by 26 %. The results are influenced by the design of the shear reinforcement.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20102 - Construction engineering, Municipal and structural engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/TH04020431" target="_blank" >TH04020431: Rozšíření aplikační oblasti FRP výztuží v betonových konstrukcích</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Solid State Phenomena
ISBN
978-80-907611-6-2
ISSN
1662-9779
e-ISSN
—
Počet stran výsledku
8
Strana od-do
151-158
Název nakladatele
Trans Tech Publications Ltd
Místo vydání
Switzerland
Místo konání akce
Praha
Datum konání akce
19. 5. 2022
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—