Decline in the Ultrasonic Pulse Velocity in Ceramic Tiles Depending on the Adhesive
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F23%3APU149761" target="_blank" >RIV/00216305:26110/23:PU149761 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1063/5.0136983" target="_blank" >http://dx.doi.org/10.1063/5.0136983</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1063/5.0136983" target="_blank" >10.1063/5.0136983</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Decline in the Ultrasonic Pulse Velocity in Ceramic Tiles Depending on the Adhesive
Popis výsledku v původním jazyce
The paper describes an experiment aimed at verifying the influence of the size of large-format tile segments and, primarily, the influence of various adhesives on the quality and behaviour of the tiles. Large-format tiles were attached in various ways to pre-prepared concrete panels with a thickness of 150 mm and surface dimensions of 2 m x 3 m. The adhesives used were varied as well as the size to which the large-format elements were cut. The quality of the tiling material was monitored non-destructively by running an ultrasonic pulse velocity test. It was found that while the size of the segments cut from the large-format tiles did not affect the ultrasonic pulse velocity, the adhesive used did.
Název v anglickém jazyce
Decline in the Ultrasonic Pulse Velocity in Ceramic Tiles Depending on the Adhesive
Popis výsledku anglicky
The paper describes an experiment aimed at verifying the influence of the size of large-format tile segments and, primarily, the influence of various adhesives on the quality and behaviour of the tiles. Large-format tiles were attached in various ways to pre-prepared concrete panels with a thickness of 150 mm and surface dimensions of 2 m x 3 m. The adhesives used were varied as well as the size to which the large-format elements were cut. The quality of the tiling material was monitored non-destructively by running an ultrasonic pulse velocity test. It was found that while the size of the segments cut from the large-format tiles did not affect the ultrasonic pulse velocity, the adhesive used did.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Special Concrete and Composites 2021
ISBN
978-0-7354-4514-7
ISSN
0094-243X
e-ISSN
—
Počet stran výsledku
5
Strana od-do
„020011-1“-„020011-5“
Název nakladatele
AIP Conference Proceedings
Místo vydání
College Park, Maryland
Místo konání akce
Skalský Dvůr
Datum konání akce
13. 10. 2021
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—