Foundation of timber structures - crawl space heat and moisture analysis with air age simulation and occurrence of micromycetes
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F26%3A0199488" target="_blank" >RIV/00216305:26110/26:0199488 - isvavai.cz</a>
Výsledek na webu
<a href="https://df.tuzvo.sk/sites/default/files/10-01-25_0_0.pdf" target="_blank" >https://df.tuzvo.sk/sites/default/files/10-01-25_0_0.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.17423/afx.2025.67.1.10" target="_blank" >10.17423/afx.2025.67.1.10</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Foundation of timber structures - crawl space heat and moisture analysis with air age simulation and occurrence of micromycetes
Popis výsledku v původním jazyce
This study is focused on the analysis of the crawl space microclimate in timber structures in the Czech Republic. It focused on the conditions in which the timber and fiberboard elements of the crawl space ceiling structure are located. As part of the analysis, air temperature, relative humidity, air flow within the crawl space were monitored. The average relative humidity within the crawl space reached up to 85% in summer and up to 90% in winter. The residence time of air in the crawl space was determined using air age simulation. A long residence time of air in the crawl space may pose a risk of capturing mold spores on the crawl space wall and ceiling surfaces. OpenFOAM software was used for the simulations. The analysis revealed the presence of fungal spores of the genera Penicillium, Aspergillus, and Cladosporium.
Název v anglickém jazyce
Foundation of timber structures - crawl space heat and moisture analysis with air age simulation and occurrence of micromycetes
Popis výsledku anglicky
This study is focused on the analysis of the crawl space microclimate in timber structures in the Czech Republic. It focused on the conditions in which the timber and fiberboard elements of the crawl space ceiling structure are located. As part of the analysis, air temperature, relative humidity, air flow within the crawl space were monitored. The average relative humidity within the crawl space reached up to 85% in summer and up to 90% in winter. The residence time of air in the crawl space was determined using air age simulation. A long residence time of air in the crawl space may pose a risk of capturing mold spores on the crawl space wall and ceiling surfaces. OpenFOAM software was used for the simulations. The analysis revealed the presence of fungal spores of the genera Penicillium, Aspergillus, and Cladosporium.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20102 - Construction engineering, Municipal and structural engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Acta Facultatis Xylologiae Zvolen
ISSN
1336-3824
e-ISSN
—
Svazek periodika
67
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
SK - Slovenská republika
Počet stran výsledku
16
Strana od-do
109-124
Kód UT WoS článku
001544201000010