STRESS-STRAIN ANALYSIS OF SURGICAL CONNECTION OF ARTERIES
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F03%3APU41529" target="_blank" >RIV/00216305:26210/03:PU41529 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
STRESS-STRAIN ANALYSIS OF SURGICAL CONNECTION OF ARTERIES
Popis výsledku v původním jazyce
A computational model of surgical connection of two identical parts of arteries is presented in the paper as an example of stress-strain analysis of vascular anastomoses realized using finite element method. The axisymmetric model assumes hommogeneous isotropic incompressible non-linear elastic material behaviour. The model is loaded by inner pressure and by axial prestretch in the range of normal physiologic values. In addition, it uses a fictive temperature field method to take residual stresses in tthe arterial wall into account. The extreme stress values in the connection of both parts are compared with compared to the stress components in the intact aorta. Allthough the model is rather simplified, it enables us to evaluate the risk of clinical complications related to mechanics (aneurysma initiation, leackage, wall rupture) by comparison of the stress increase in the individual types and geometries of anastomoses.
Název v anglickém jazyce
STRESS-STRAIN ANALYSIS OF SURGICAL CONNECTION OF ARTERIES
Popis výsledku anglicky
A computational model of surgical connection of two identical parts of arteries is presented in the paper as an example of stress-strain analysis of vascular anastomoses realized using finite element method. The axisymmetric model assumes hommogeneous isotropic incompressible non-linear elastic material behaviour. The model is loaded by inner pressure and by axial prestretch in the range of normal physiologic values. In addition, it uses a fictive temperature field method to take residual stresses in tthe arterial wall into account. The extreme stress values in the connection of both parts are compared with compared to the stress components in the intact aorta. Allthough the model is rather simplified, it enables us to evaluate the risk of clinical complications related to mechanics (aneurysma initiation, leackage, wall rupture) by comparison of the stress increase in the individual types and geometries of anastomoses.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BO - Biofyzika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2003
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Engineering Mechanics 2003
ISBN
80-86246-18-3
ISSN
—
e-ISSN
—
Počet stran výsledku
2
Strana od-do
302-303
Název nakladatele
Association fo Engineering Mechanics
Místo vydání
Svratka, CZ
Místo konání akce
Svratka
Datum konání akce
12. 5. 2003
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—