Solární komíny pro větrání obytných budov
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F04%3APU45922" target="_blank" >RIV/00216305:26210/04:PU45922 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
SOLAR CHIMNEYS FOR RESIDENTIAL VENTILATION
Popis výsledku v původním jazyce
An increasing impact of ventilation and air-conditioning to the total energy consumption of buildings has drawn attention to natural ventilation and passive cooling. The very common way of natural ventilation in residential buildings is passive stack ventilation. The passive stack ventilation relies on the stack effect created by the temperature difference between air temperature inside and outside a building. A solar chimney represents an option how to improve the performance of passive stack ventilaation on hot sunny days, when there is a small difference between indoor and outdoor air temperature. The full-scale solar chimneys have been built and tested at the Department of Thermodynamics and Environmental Engineering at the Brno University of Technology. The main goal of the experiments is to investigate performance of solar chimneys under the climatic conditions of the Czech Republic. Two different constructions of a solar chimney have been tested; a light weight construction and
Název v anglickém jazyce
SOLAR CHIMNEYS FOR RESIDENTIAL VENTILATION
Popis výsledku anglicky
An increasing impact of ventilation and air-conditioning to the total energy consumption of buildings has drawn attention to natural ventilation and passive cooling. The very common way of natural ventilation in residential buildings is passive stack ventilation. The passive stack ventilation relies on the stack effect created by the temperature difference between air temperature inside and outside a building. A solar chimney represents an option how to improve the performance of passive stack ventilaation on hot sunny days, when there is a small difference between indoor and outdoor air temperature. The full-scale solar chimneys have been built and tested at the Department of Thermodynamics and Environmental Engineering at the Brno University of Technology. The main goal of the experiments is to investigate performance of solar chimneys under the climatic conditions of the Czech Republic. Two different constructions of a solar chimney have been tested; a light weight construction and
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BK - Mechanika tekutin
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GP101%2F04%2FP033" target="_blank" >GP101/04/P033: Hybridní větrání obytných budov s využitím solárních komínů</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
25th AIVC Conference - Ventilation and Retrofitting
ISBN
2-9600355-6-9
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
19-24
Název nakladatele
NEUVEDEN
Místo vydání
NEUVEDEN
Místo konání akce
Prague
Datum konání akce
15. 9. 2004
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—