Mechanická analýza kontaktu mezi hlavicí a jamkou TEP kyčelního kloubu
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F05%3APU55220" target="_blank" >RIV/00216305:26210/05:PU55220 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
MECHANICAL ANALYSIS OF CONTACT BETWEEN BALL HEAD AND ACETABULAR FOSSA OF TOTAL HIP PROSTHESIS
Popis výsledku v původním jazyce
Summary: This paper belongs to biomechanics of a hip joint section. It is engaged in problems with industrial tolerances for dimensions as one of the possible total hip prosthesis insufficiency. There can be a lot of reasons for failing of hip prosthesis(for example unfit materials, unfit construction, etc.). And there are also a lot of types of failure (for example break of prosthesis, pull-off of the components etc.). It was found that there is not uniform abrasion on removed parts from human body dduring the analysis on components of total hip prosthesis. On unused parts it was found that there are not the same tolerances for dimensions at the same components from different producers. During the pushing of the ball head into acetabulum we can findout that some pairs show out a clearance, some show the interference and in some cases we can say that they have a fine fit. 2D and 3D computation models of a ball head, acetabular fossa and pelvis were made, on which interference or clear
Název v anglickém jazyce
MECHANICAL ANALYSIS OF CONTACT BETWEEN BALL HEAD AND ACETABULAR FOSSA OF TOTAL HIP PROSTHESIS
Popis výsledku anglicky
Summary: This paper belongs to biomechanics of a hip joint section. It is engaged in problems with industrial tolerances for dimensions as one of the possible total hip prosthesis insufficiency. There can be a lot of reasons for failing of hip prosthesis(for example unfit materials, unfit construction, etc.). And there are also a lot of types of failure (for example break of prosthesis, pull-off of the components etc.). It was found that there is not uniform abrasion on removed parts from human body dduring the analysis on components of total hip prosthesis. On unused parts it was found that there are not the same tolerances for dimensions at the same components from different producers. During the pushing of the ball head into acetabulum we can findout that some pairs show out a clearance, some show the interference and in some cases we can say that they have a fine fit. 2D and 3D computation models of a ball head, acetabular fossa and pelvis were made, on which interference or clear
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JR - Ostatní strojírenství
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
INŽENÝRSKÁ MECHANIKA 2005
ISBN
80-85918-93-5
ISSN
—
e-ISSN
—
Počet stran výsledku
2
Strana od-do
165-166
Název nakladatele
—
Místo vydání
Brno
Místo konání akce
Svratka
Datum konání akce
9. 5. 2005
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—