The basis for room air distribution solutions in ventilating and air conditioning rooms is the calcula-tion of velocities in air jets from supply outlets. To calculate velocities, the C-value of the air outlets must be known. The outlet C-values are specified for each type of outlet experimentally. The aim of this contribution is to acquaint readers with nontraditional methods for defining the C-value of an outlet from the angle of air jet expansion in the main jet zone, determined using interferometricc visu-alization of the jet. To visualize the air jet from the outlet, a Mach-Zehnder interferometer is used which allows accurate, quality interferometric records to be obtained over the entire field of view of the jet. This contribution describes the dependence of the outlet C-value on the expansion angle of the main jet zone. The principles of interferometric measurements in transparent environments are dem-onstrated, along with their evaluation via special software developed for eval
Název v anglickém jazyce
Determination of air outlet C values by means of interferometry
Popis výsledku anglicky
The basis for room air distribution solutions in ventilating and air conditioning rooms is the calcula-tion of velocities in air jets from supply outlets. To calculate velocities, the C-value of the air outlets must be known. The outlet C-values are specified for each type of outlet experimentally. The aim of this contribution is to acquaint readers with nontraditional methods for defining the C-value of an outlet from the angle of air jet expansion in the main jet zone, determined using interferometricc visu-alization of the jet. To visualize the air jet from the outlet, a Mach-Zehnder interferometer is used which allows accurate, quality interferometric records to be obtained over the entire field of view of the jet. This contribution describes the dependence of the outlet C-value on the expansion angle of the main jet zone. The principles of interferometric measurements in transparent environments are dem-onstrated, along with their evaluation via special software developed for eval
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BK - Mechanika tekutin
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/OC%20G3.20" target="_blank" >OC G3.20: Výzkum teplotních polí v průmyslových budovách při různých podmínkách větrání a vytápění</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
The international journal of ventilation
ISSN
1473-3315
e-ISSN
—
Svazek periodika
4
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
12
Strana od-do
311-322