Numerická simulace přesného lití
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F06%3APU63178" target="_blank" >RIV/00216305:26210/06:PU63178 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Numerical Simulation of the Investment Casting
Popis výsledku v původním jazyce
Problematic of a heat flux in the investment casting is specific against the other casting technologies. Thickness and volume of a shell is much lower then other types of molds. Also an accumulation of the heat in a shell is much lower so most of the heat is radiated to environment. It is needed to know heat transfer parameters and coefficients for accurate simulation. This work is aimed to measuring and computing coefficient of the heat transfer between shell-mold and metal and computing of emisivity of the shell. The start of this work was measuring of emissivity. A thermo camera and thermocouples were used as measuring equipment. Also a pyrometer was used to measure this value but using the thermo camera seems as more accurate. Correct value of theheat transfer coefficient was needed to improve a prediction of casting defects by simulations. It can not be directly measured. Value of the heat transfer coefficient for shell-casting system must be obtained in two steps. The first step
Název v anglickém jazyce
Numerical Simulation of the Investment Casting
Popis výsledku anglicky
Problematic of a heat flux in the investment casting is specific against the other casting technologies. Thickness and volume of a shell is much lower then other types of molds. Also an accumulation of the heat in a shell is much lower so most of the heat is radiated to environment. It is needed to know heat transfer parameters and coefficients for accurate simulation. This work is aimed to measuring and computing coefficient of the heat transfer between shell-mold and metal and computing of emisivity of the shell. The start of this work was measuring of emissivity. A thermo camera and thermocouples were used as measuring equipment. Also a pyrometer was used to measure this value but using the thermo camera seems as more accurate. Correct value of theheat transfer coefficient was needed to improve a prediction of casting defects by simulations. It can not be directly measured. Value of the heat transfer coefficient for shell-casting system must be obtained in two steps. The first step
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JR - Ostatní strojírenství
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
43rd Foundry Days CD
ISBN
80-214-3244-6
ISSN
—
e-ISSN
—
Počet stran výsledku
1
Strana od-do
1-1
Název nakladatele
ČESKÁ SLÉVÁRENSKÁ SPOLEČNOST
Místo vydání
Brno
Místo konání akce
Brno
Datum konání akce
14. 11. 2006
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—